Real-Time I/Q Baseband Generator User’s and Programming Guide
4-7
ESG Family Signal Generators
Programming Commands and Examples
Options UN8 and 202
Programming Commands
DECT - Radio Fixed Part Low Capacity with Z Field Timeslot
[:SOURce]:RADio:DECT:RFPart:SLOT0|[1]|2|3|4|5|6|7|8|9|10|
11:ZLCapacity[:B] PN9|PN15|FIX4|"<file name>"|EXT|FDEV1_HS|FDEV1_FS|
FDEV2_FS|FACCuracy| DM1|DM0|P4|P8|P16|P32|P64
[:SOURce]:RADio:DECT:RFPart:SLOT0|[1]|2|3|4|5|6|7|8|9|10|11:ZLCapacity
[:B]?
This command enables you to set the B field’s data pattern for the selected low capacity
with Z field timeslot in the radio fixed part during framed data transmission. The choices
are timeslots 0 through 11 and PN9 (pseudorandom bit pattern), PN15 (pseudorandom bit
pattern), FIX4 (4-bit repeating sequence data pattern), "<file name>" (a file in the catalog
of binary files), Ext (external input data pattern), half-slot frequency deviation (8 bits of 10
followed by 32 ones, 32 zeros, and 8 bits of 10), full-slot frequency deviation #1 (128 bits of
10, followed by 64 ones, 64 zeros, and 64 bits of 10), full-slot frequency deviation #2 (the
bits 10 repeated as necessary to fill the selected data area), frequency accuracy (the bits
11110000 repeated as necessary to fill the selected data area), DM1 (all 1’s repeated as
necessary to fill the selected data area), DM0 (all 0’s repeated as necessary to fill the
selected data area),P4 (four 1’s and four 0’s), P8 (eight 1’s and eight 0’s), P16 (sixteen 1’s
and sixteen 0’s), P32 (thirty-two 1’s and thirty-two 0’s), or P64 (sixty-four 1’s and sixty-four
0’s).
*RST value: PN9
DECT - Radio Fixed Part Traffic Bearer Timeslot
[:SOURce]:RADio:DECT:RFPart:SLOT0|[1]|2|3|4|5|6|7|8|9|10|
11:TRAFfic[:B] PN9|PN15|FIX4|"<file name>"|EXT|FDEV1_HS|FDEV1_FS|
FDEV2_FS|FACCuracy|DM1| DM0|P4|P8|P16|P32|P64
[:SOURce]:RADio:DECT:RFPart:SLOT0|[1]|2|3|4|5|6|7|8|9|10|11:TRAFfic[:B]?
This command enables you to set the B field’s data pattern for the selected traffic bearer
timeslot in the radio fixed part during framed data transmission. The choices are timeslots
0 through 11 and PN9 (pseudorandom bit pattern), PN15 (pseudorandom bit pattern),
FIX4 (4-bit repeating sequence data pattern), "<file name>" (a file in the catalog of binary
files), Ext (external input data pattern), half-slot frequency deviation (8 bits of 10 followed
by 32 ones, 32 zeros, and 8 bits of 10), full-slot frequency deviation #1 (128 bits of 10,
followed by 64 ones, 64 zeros, and 64 bits of 10), full-slot frequency deviation #2 (the bits 10
repeated as necessary to fill the selected data area), frequency accuracy (the bits 11110000
repeated as necessary to fill the selected data area), DM1 (all 1’s repeated as necessary to
fill the selected data area), DM0 (all 0’s repeated as necessary to fill the selected data
area),P4 (four 1’s and four 0’s), P8 (eight 1’s and eight 0’s), P16 (sixteen 1’s and sixteen 0’s),
P32 (thirty-two 1’s and thirty-two 0’s), or P64 (sixty-four 1’s and sixty-four 0’s).
*RST value: PN9
Summary of Contents for ESG series
Page 2: ...ii ...
Page 446: ...I 16 Index Index ...