Real-Time I/Q Baseband Generator User’s and Programming Guide
3-143
ESG Family Signal Generators
Softkey Reference
Options UN8 and 202
R
Restore Default Burst Shape
Press this softkey to reset the burst parameters to their default values.
You can also use other keys in this menu to change each of the burst
characteristics individually.
Default Values
Softkey Locations
Custom:
Mode
>
Custom
>
Burst Shape
>
Restore Default Burst Shape
Other Formats:
Mode
>
TDMA
>
desired format
>
Modify Standard
>
Burst Shape
>
Restore Default Burst Shape
Restore Default Filter
Press this softkey to replace the current FIR filter with the default
filter.
Default Values
Custom, NADC, and TETRA: Root Nyquist
α
= 0.350
DECT: Gaussian BbT = 0.500
EDGE: EDGE
GSM: Gaussian BbT = 0.300
PDC and PHS: Root Nyquist
α
= 0.500
Rise Time,
bits
Rise Delay,
bits
Fall Time,
bits
Fall Delay,
bits
Shape
Type
Custom
5.860
0.000
5.470
0.000
sine
DECT
13.797
–3.250
11.529
2.875
sine
EDGE
12.700
4.400
10.300
1.200
sine
GSM
4.224
0.000
3.440
0.125
sine
NADC
5.860
–1.000
5.470
–1.000
sine
PDC
5.470
0.000
3.830
–0.500
sine
PHS
4.976
–1.500
4.544
–1.500
sine
TETRA
9.376
–1.000
7.814
0.000
sine
Summary of Contents for ESG series