Real-Time I/Q Baseband Generator User’s and Programming Guide
3-91
ESG Family Signal Generators
Softkey Reference
Options UN8 and 202
F
Fall Time
Press this softkey to make the burst shape fall time the active function.
Range: depends on the modulation type and the symbol rate
Default Values
Custom: 5.470
NADC: 5.470
DECT: 11.529
PDC: 3.830
EDGE: 10.300
PHS: 4.544
GSM: 3.440
TETRA: 7.814
Softkey Locations
Custom:
Mode
>
Custom
>
Burst Shape
>
Fall Time
Other Formats:
Mode
>
TDMA
>
desired format
>
Modify Standard
>
Burst Shape
>
Fall Time
FCOR
Press this softkey to make the 80-bit frequency correction bits (FCOR)
the active function. The preset hexadecimal value reflects the TETRA
format, and appears in the
FCOR
field near the bottom of the text area of
the display.
Default Value: FF0000000000000000FF
Softkey Location:
Mode
>
TDMA
>
TETRA
>
Data Format Pattern Framed
>
Configure Timeslots
>
Timeslot Type
>
Dn Sync Cont
>
Configure Dn Sync Cont
>
FCOR
Or:
Mode
>
TDMA
>
TETRA
>
Data Format Pattern Framed
>
Configure Timeslots
>
Timeslot Type
>
Dn Sync Disc
>
Configure Dn Sync Disc
>
FCOR
FCorr
Press this softkey to select frequency correction as the timeslot type for
the active timeslot. Frequency correction is a burst where all of the bits
are set to zero. This burst is used for synchronizing the mobile to the
correct frequency.
When you select
FCorr
for a timeslot, the visual representation of the
timeslot pattern updates.
Softkey Location:
Mode
>
TDMA
>
GSM
>
Data Format Pattern Framed
>
Configure Timeslots
>
Timeslot Type
>
FCorr
Summary of Contents for ESG series