
3-76
Real-Time I/Q Baseband Generator User’s and Programming Guide
Softkey Reference
ESG Family Signal Generators
D
Options UN8 and 202
DM0
Press this softkey to select a binary data pattern that consists of all
zeroes. This internally-generated data pattern is available for framed
transmissions only. When
DM0
is selected, both the
B field
and the
Dect Patterns
softkeys show this selection, and
DM0
appears in the
B
field, near the bottom of the text area of the display.
Softkey Location:
Mode
>
TDMA
>
DECT
>
Data Format Pattern Framed
>
Configure Timeslots
>
Configure Traffic Bearer
>
B field
>
Dect Patterns
>
DM0
DM0
is also located in the Dect Patterns menus found in the portable
part Configure Traffic Bearer menu and the radio fixed part and
portable part Low Capacity menus, and also in the radio fixed part and
portable part Configure Custom menus.
DM1
Press this softkey to select a binary data pattern that consists of all
ones. This internally-generated data pattern is available for framed
transmissions only. When
DM1
is selected, both the
B field
and the
Dect Patterns
softkeys show this selection, and
DM1
appears in the
B
field, near the bottom of the text area of the display.
Softkey Location:
Mode
>
TDMA
>
DECT
>
Data Format Pattern Framed
>
Configure Timeslots
>
Configure Traffic Bearer
>
B field
>
Dect Patterns
>
DM1
DM1
is also located in the Dect Patterns menus found in the portable
part Configure Traffic Bearer menu and the radio fixed part and
portable part Low Capacity menus, and also in the radio fixed part and
portable part Configure Custom menus.
Dn Custom Cont
Press this softkey to select a downlink continuous custom timeslot type
for the active timeslot, which is configured using an
internally-generated data pattern, a downloaded sequence of bits
stored in a user file, or by supplying external data. This timeslot is
provided for flexibility; it is not a standard TETRA timeslot. You cannot
mix downlink and uplink timeslots. If a timeslot is designated as
uplink, it changes to downlink if any other timeslot is designated as
downlink. The following table shows the change to a frame designated
as uplink when you select either continuous downlink or discontinuous
downlink. When you select a timeslot, the display updates.
Softkey Location:
Mode
>
TDMA
>
TETRA
>
Data Format Pattern Framed
>
Configure Timeslots
>
Timeslot Type
>
Dn Custom Cont
From Uplink
Timeslot
To Continuous
Downlink Timeslot
To Discontinuous
Downlink Timeslot
Up Custom
Dn Custom Cont
Dn Custom Disc
Up Control 1
Dn Custom Cont
Dn Custom Disc
Up Control 2
Dn Custom Cont
Dn Custom Disc
Summary of Contents for ESG series
Page 2: ...ii ...
Page 446: ...I 16 Index Index ...