3-34
Real-Time I/Q Baseband Generator User’s and Programming Guide
Softkey Reference
ESG Family Signal Generators
C
Options UN8 and 202
Configure Dn Normal Cont
Pressing this softkey displays a menu of softkeys where you can
configure a timeslot as a downlink continuous normal timeslot. The
display in the following figure shows each field of the timeslot as it is
defined by the TETRA format.
•
TS1:
shows that the 12-bit training sequence field always contains
hexadecimal 1AD. The grey text in this field indicates that you
cannot change it.
•
PA:
there are two 2-bit phase adjustment fields. The grey text in
these fields indicates that you cannot change their content.
•
Data:
shows the data selection (PN9) for both 216-bit data fields.
Other selections include PN15, fixed 4-bit patterns, fixed patterns of
ones and zeroes, user files, or external data.
•
B1:
shows the contents of the 14-bit broadcast bits field
(hexadecimal 0000). The
B1
softkey makes this the active function.
•
TS2:
shows the contents (hexadecimal 343A74) of the 22-bit training
sequence field. The
TS
softkey makes this the active function.
•
B2:
shows contents (hexadecimal 0000) of the 16-bit broadcast bits
field. The
B2
softkey makes this the active function.
•
TS3:
shows the contents (hexadecimal 2DC) of the 10-bit training
field. The grey text in this field indicates that you cannot change it.
Softkey Location:
Mode
>
TDMA
>
TETRA
>
Data Format Pattern Framed
>
Configure Timeslots
>
Timeslot Type
>
Dn Normal Cont
>
Configure Dn Normal Cont