Real-Time I/Q Baseband Generator User’s and Programming Guide
2-27
HP ESG Family Signal Generators
Using Functions
Options UN8 and 202
Creating User-Defined FIR Filters
2. Note that the coefficient 0 Value field is highlighted. Use the numeric keypad to type
the first value from the list. As you press the numeric keys, the numbers appear in the
active entry area. (If you make a mistake, you can correct it using the backspace key.)
Terminate the entry by pressing the
Enter
softkey. Note that the value for coefficient 0 is
now displayed in the Value field and a second row is automatically displayed with the
Value field highlighted. (The following illustration shows the FIR table editor at this
point in the process.)
3. Continue entering the coefficient values until all 16 are complete.
Coefficient
Value
Coefficient
Value
0
−
0.000076
8
−
0.035667
1
−
0.001747
9
−
0.116753
2
−
0.005144
10
−
0.157348
3
−
0.004424
11
−
0.088484
4
0.007745
12
0.123414
5
0.029610
13
0.442748
6
0.043940
14
0.767329
7
0.025852
15
0.972149