4-86
Real-Time I/Q Baseband Generator User’s and Programming Guide
Programming Commands and Examples
ESG Family Signal Generators
Programming Commands
Options UN8 and 202
TETRA - Uplink Normal Timeslot
[:SOURce]:RADio:TETRa:SLOT[1]|2|3|4:UNORmal:TSEQuence <22-bit value>
[:SOURce]:RADio:TETRa:SLOT[1]|2|3|4:UNORmal:TSEQuence?
This command specifies the extended training sequence bits (22-bit midamble) for the
selected uplink normal timeslot. When 1E90DE is selected, the data fields are scrambled
as separate logical channels.
Range: 000000 to 3FFFFF
*RST value: 343A74
Trigger Source
[:SOURce]:RADio:CUSTom:TRIGger[:SOURce] KEY|EXT|BUS
[:SOURce]:RADio:CUSTom:TRIGger[:SOURce]?
[:SOURce]:RADio:<desired format>:TRIGger[:SOURce] KEY|EXT|BUS
[:SOURce]:RADio:<desired format>:TRIGger[:SOURce]?
This command sets the mode for triggering your unframed data pattern. The choices are
Key (trigger using the front panel
Trigger
key), Ext (trigger using an external trigger
supplied to the TRIGGER IN connector), or Bus (trigger with a command sent over GPIB).
Pattern Trigger is not available with either a PN data sequence, or an external data
source.
*RST value: Key
Unique Word Field
PHS - Downlink Synchronization Channel Timeslot
[SOURce]:RADio:PHS:DLINK:SLOT[1]|2|3|4:SCHannel:UWORd <bit pattern>
[SOURce]:RADio:PHS:DLINK:SLOT[1]|2|3|4:SCHannel:UWORd?
This command enables you to change the unique word (UW) field. The preset hexadecimal
value (when normal preset is selected) for UW reflects the PHS protocol, however you can
enter a new value entering this command. The UW value becomes the active function. The
current value for UW is displayed in the
UW
field near the bottom of the text area of the
display.
Range: 000000000 to 0FFFFFFFF
*RST value: 050EF2993