Agilent E5052BU Option 018

Hard Disk Drive Kit

User’s Guide

First Edition

Manufacturing No.  E5052-90202

May 2007

Summary of Contents for E5052B

Page 1: ...Agilent E5052BU Option 018 Hard Disk Drive Kit User s Guide First Edition Manufacturing No E5052 90202 May 2007 ...

Page 2: ...orated at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated May 2007 First Edition Typeface Conventions Sample bold Boldface type is used when a term is defined or emphasis Sample Italic Italic type is used for emphasis key Indicates a hardkey key on the front panel or external keyboard labeled Sample key may be omitted Sample ...

Page 3: ...3 1 General Information This chapter describes the Hard Disk Drive Kit contents of the kit and required tools to install the Option 018 into the Agilent E5052B ...

Page 4: ... 018 into the Agilent E5052B Contents of the Agilent E5052BU Option 018 Hard Disk Drive Kit The kit includes the parts listed in Table 1 1 If anything is missing contact the nearest Agilent Technologies office Table 1 1 Contents of the Agilent E5052BU Option 018 Hard Disk Drive Kit Description Qty Upgrade Manual This manual 1 HDD Assembly 1 ...

Page 5: ...5 2 Option Installation This chapter describes the procedure to install the option 018 into the Agilent E5052B ...

Page 6: ...llation Requirement Saving System calibration Data from Removable Hard Disk to USB Pen Drive Removing Removable Hard Disk Mounting Removable Hard Disk Initial Registration of E5052B Calibration of the Touch Screen Recalling System Calibration Data from USB Pen drive to Removable Hard Disk Procedure Installation Requirement 5188 4426 Key for Hard Disk Carrier USB Pen Drive Over 512MB ...

Page 7: ...drive into the USB port in front panel Step 3 Open D Recovery drive Step 4 Click D syscal from the explorer Step 5 Select Edit Copy from menu bar of the explorer Step 6 Click the USB Pen drive of the explorer Step 7 Select Edit Paste from menu bar of the explorer Step 8 Click D limit from the explorer Step 9 Select Edit Copy from menu bar of the explorer Step 10 Click the USB Pen drive of the expl...

Page 8: ...ower Step 2 Insert the key in the lock and turn anti clockwise Step 3 Open the screw in clockwise direction Step 4 Press the button under direction Step 5 Remove the hard disk Mounting Removable Hard Disk Follow the steps below to mount a removable hard disk Step 1 Insert the hard disk into the slot Step 2 Turn the screw in anti clockwise direction until it is locked Step 3 Turn the key to the rig...

Page 9: ...B therefore connect the mouse and the keyboard before turning on the power NOTE If you perform the following procedure incorrectly a message asking you whether to return to the previous registration screen and perform the registration appears In this case follow the instruction to return to the previous registration screen Step 1 Turns on the E5052B Step 2 The Windows XP Professional Setup wizard ...

Page 10: ...ext button Figure 2 2 Figure 2 2 Windows XP Professional Setup dialog box 1 2 Step 4 In the next dialog box input E5052 in the Name box Then click the Next button Figure 2 3 Figure 2 3 Windows XP Professional Setup dialog box 2 2 Step 5 After a while the E5052B restart automatically Then the measurement display appears e5071cse1074 e5052bse1033 E5052 ...

Page 11: ...h screen calibration screen Figure 2 4 appears Figure 2 4 Touch Panel Calibration Screen Step 5 Touch the x mark on the upper left with your finger The mark x appears also on the lower left upper right and lower right Touch the x marks in that order with your finger Touching the four locations described above with your finger automatically concludes the touch screen calibration NOTE With no operat...

Page 12: ...52B OK Step 2 Insert a USB pen drive in to the USB port in front panel Step 3 Open D Recovery drive Step 4 Click syscal folder in the USB Pen drive from the explorer Step 5 Select Edit Copy from menu bar of the explorer Step 6 Click the D of the explorer Step 7 Select Edit Paste from menu bar of the explorer Step 8 Click limit folder in the USB Pen drive from the explorer Step 9 Select Edit Copy f...

Page 13: ... 1 800 452 4844 fax 1 888 900 8921 Canada Test and Measurement Call Center tel 1 877 894 4414 fax 1 888 900 8921 China tel 800 810 0189 fax 800 820 2816 Europe tel 31 20 547 2323 fax 31 20 547 2390 Japan Call Center tel 0120 421 345 tel 81 426 56 7832 fax 81 426 56 7840 Korea tel 82 2 2004 5004 fax 82 2 2004 5115 Latin America tel 305 269 7500 fax 305 269 7599 Taiwan tel 0800 047 866 fax 0800 286 ...