Chapter 18
653
Troubleshooting
Signal Generator Lock-Up
Signal Generator Lock-Up
If the signal generator is locked up, check the following:
•
Make sure that the signal generator is not in remote mode. (In remote mode, the
R
annunciator will
appear on the display.) Press
Local
to exit remote mode and unlock the front panel keypad.
•
Make sure that the signal generator is not in local lockout condition. Local lockout will prevent front
panel operation of the signal generator. For more information on local lockout, refer to the
E4428C/38C
ESG Signal Generators Programming Guide
.
•
Check for a progress bar on the signal generator display which indicates that an operation is in progress.
•
Press
Preset
.
•
Cycle power on the signal generator.
Fail-Safe Recovery Sequence
The fail-safe recovery sequence should only be used if the previous suggestions do not resolve the problem.
NOTE
This process will reset the signal generator, but it will destroy data.
The fail-safe recovery sequence will destroy the following types of data:
•
all user files (instrument state and data files)
•
DCFM/DC
Φ
M calibration data
•
persistent states
Do not attempt to perform any other front panel or remote operations during the fail-safe sequence.
To run the fail-safe sequence, follow these steps:
1. Hold down the
Preset
key while cycling power.
Summary of Contents for E4428C
Page 22: ...Contents xxii ...
Page 224: ...200 Chapter 4 Basic Digital Operation Creating and Using Bit Files ...
Page 228: ...204 Chapter 5 AWGN Waveform Generator Configuring the AWGN Generator ...
Page 229: ...205 6 Analog Modulation ...
Page 276: ...252 Chapter 7 Digital Signal Interface Module Operating the N5102A Module in Input Mode ...
Page 286: ...262 Chapter 8 Bluetooth Signals Turning On a Bluetooth Signal ...
Page 330: ...306 Chapter 9 BERT Verifying BERT Operation ...
Page 366: ...342 Chapter 10 CDMA Digital Modulation IS 95A Modulation ...
Page 394: ...370 Chapter 12 Multitone Waveform Generator Applying Changes to an Active Multitone Signal ...
Page 468: ...444 Chapter 15 W CDMA Digital Modulation for Component Test W CDMA Frame Structures ...
Page 667: ...643 18 Troubleshooting ...
Page 700: ...Index 676 Index ...