Chapter 9
271
BERT
Measuring RF Loopback BERT with Option 300
Configuring GSM Mode on the Agilent Technologies E4406A VSA Series Transmitter Tester
The following steps will show you how to set up the vector signal analyzer (VSA) for synchronization.
1. To preset the VSA:
Press
Preset
.
2. To select GSM mode:
Press
MODE
>
GSM
.
3. To set up GSM mode for BTS test:
Press
Mode Setup
>
Radio
>
Band
>
P-GSM > Return
.
Toggle
Device BTS MS
until BTS is underlined.
Toggle
Freq Hopping On Off
until Off is underlined.
4. To set the frequency:
Press
FREQUENCY Channel
>
ARFCN 124
.
Center Freq will show
959.800 MHz
.
Select
Burst Type
>
Normal
.
Toggle
TSC (Std)
until Auto is underlined.
5. To lock the VSA and ESG to the BTS 13 MHz reference:
Press
System
>
Reference
>
Freq Ref
>
13
>
MHz
.
Toggle
Freq Ref Int Ext
until Ext is underlined.
Toggle
10 MHz Out Off On
until On is underlined.
Summary of Contents for E4428C
Page 22: ...Contents xxii ...
Page 224: ...200 Chapter 4 Basic Digital Operation Creating and Using Bit Files ...
Page 228: ...204 Chapter 5 AWGN Waveform Generator Configuring the AWGN Generator ...
Page 229: ...205 6 Analog Modulation ...
Page 276: ...252 Chapter 7 Digital Signal Interface Module Operating the N5102A Module in Input Mode ...
Page 286: ...262 Chapter 8 Bluetooth Signals Turning On a Bluetooth Signal ...
Page 330: ...306 Chapter 9 BERT Verifying BERT Operation ...
Page 366: ...342 Chapter 10 CDMA Digital Modulation IS 95A Modulation ...
Page 394: ...370 Chapter 12 Multitone Waveform Generator Applying Changes to an Active Multitone Signal ...
Page 468: ...444 Chapter 15 W CDMA Digital Modulation for Component Test W CDMA Frame Structures ...
Page 667: ...643 18 Troubleshooting ...
Page 700: ...Index 676 Index ...