Chapter 10
327
CDMA Digital Modulation
cdma2000 Forward Link Modulation for Receiver Test
Configuring the RF Output
The steps in this procedure build upon the previous procedure.
1. Set the RF output frequency to 2.14 GHz.
2. Set the output amplitude to
−
30 dBm.
3. Press
RF On/Off
to On.
The user-defined, real-time forward link cdma2000 signal is now available at the signal generator’s RF
OUTPUT connector.
To store this real-time I/Q baseband digital modulation state to the instrument state register, see
Instrument State Registers” on page 70
.
To recall a real-time I/Q baseband digital modulation state, see