Chapter 9
303
BERT
Verifying BERT Operation
2. Press the
Preset
hardkey. This configures the signal generator to a pre-defined state.
3. Press the
Mode
hardkey.
4. Press
Real TDMA
>
PHS
>
Data Format
to Pattern.
5. Press
Data
>
PN Sequence
>
PN9
>
PHS Off On
to On.
6. Press the
Aux Fctn
hardkey.
7. Press
BERT > BERT Off On
to On >
Display BER
%
Exp
to % >
Display Update Cycle End Cont
to Cont.
The following steps configure BERT measurement parameters.
8. Press
Configure BERT
>
Total Bits
to 100000 >
Special Pattern Ignore Off On
to Off.
9. Press
More (1 of 2)
>
BERT Resync Off On
to Off >
Pass/Fail Off On
to Off.
10. Press
Return
>
I/O Setup
>
Gate Off On
to Off >
Impedance 75 Ohm High
to High.
11. Press
Polarity Setup
>
Clock Polarity Pos Neg
to Neg >
Data Polarity Pos Neg
to Pos.
12. Press
Return
>
Return
>
Configure Trigger
>
Cycle Count 0
>
Enter
.
Summary of Contents for E4428C
Page 22: ...Contents xxii ...
Page 224: ...200 Chapter 4 Basic Digital Operation Creating and Using Bit Files ...
Page 228: ...204 Chapter 5 AWGN Waveform Generator Configuring the AWGN Generator ...
Page 229: ...205 6 Analog Modulation ...
Page 276: ...252 Chapter 7 Digital Signal Interface Module Operating the N5102A Module in Input Mode ...
Page 286: ...262 Chapter 8 Bluetooth Signals Turning On a Bluetooth Signal ...
Page 330: ...306 Chapter 9 BERT Verifying BERT Operation ...
Page 366: ...342 Chapter 10 CDMA Digital Modulation IS 95A Modulation ...
Page 394: ...370 Chapter 12 Multitone Waveform Generator Applying Changes to an Active Multitone Signal ...
Page 468: ...444 Chapter 15 W CDMA Digital Modulation for Component Test W CDMA Frame Structures ...
Page 667: ...643 18 Troubleshooting ...
Page 700: ...Index 676 Index ...