Chapter 4 Remote Interface Reference
Output Setting and Operation Commands
87
4
INSTrument:NSELect?
Return the currently selected output by the
INSTrument[SELect]
or
INSTrument[SELect]
command. The returned parameter is ‘‘1’’ for output1,
‘‘2’’ for output2.
INSTrument:COUPle[:TRIGger] {ON | OFF}
Enable or disable a coupling between two logical outputs of the power supply. The
couple command consists of an optional subsystem node followed by a signal
parameter. The
only
valid parameter for the optional subsystem node is
TRIGger
subsystem. If no node follows the couple command,
TRIGger
subsystem is assumed
to be coupled.
The parameter indicates to which logical outputs the specified coupling is to apply.
A list of outputs specifies a particular set of logical outputs to be coupled. At
*RST
,
all outputs are uncoupled.
Example
The following program segment shows how to use the
INSTrument:COUPle
command to couple two outputs with voltage and current triggered levels. The power
supply is set to the newly programmed values as set by the
VOLTage:TRIGgered
and
CURRent:TRIGgered
commands.
‘‘
INST:SEL OUT1
’’
Select the output1
‘‘
VOLT:TRIG 6
’’
Set triggered level to 6 V
‘‘
CURR:TRIG 3
’’
Set triggered level to 3 A
‘‘
INST:SEL OUT2
’’
Select the output2
‘‘
VOLT:TRIG 18
’’
Set triggered level to 18 V
‘‘
CURR:TRIG 0.7
’’
Set triggered level to 0.7 A
‘‘
INST:COUP:TRIG ON
’’
Couple the output1 and the output2
‘‘
TRIG:SOUR IMM
’’
Set trigger to immediate
‘‘
INIT
’’
Trigger the power supply to output the
trigger values for the output1 and output2
supplies.
INSTrument:COUPle[:TRIGger]?
Query the output coupling state of the power supply. The returned value is ‘‘0’’ (OFF)
or ‘‘1’’ (ON).
MEASure:CURRent?
Query the current measured across the current sense resistor inside the power supply.
Summary of Contents for E3646A
Page 2: ...2...
Page 16: ...16 Contents Contents...
Page 17: ...1 Quick Start...
Page 27: ...2 General Information...
Page 39: ...3 Front Panel Operation and Features...
Page 72: ...Chapter 3 Front Panel Operation and Features Calibration Overview 72...
Page 73: ...4 Remote Interface Reference...
Page 125: ...5 Error Messages...
Page 136: ...Chapter 5 Error Messages Calibration Errors 136...
Page 137: ...6 Application Programs...
Page 148: ...Chapter 6 Application Programs Example Program for Excel 97 148...
Page 149: ...7 Tutorial...
Page 160: ...Chapter 7 Tutorial Remote Programming 160...
Page 161: ...8 Specifications...
Page 169: ...Appendix Service Information...
Page 178: ...Appendix Service Information General Disassembly 178 General Disassembly...
Page 210: ......