368
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_schannel.fm
CALL:SCHannel
CALL:SCHannel[:SLEVel][:SELected]
CALL:SCHannel:DRATe[:SELected]
Function
The setting form of this command performs two functions: (1) sets the level of the forward
supplemental channel (SCH), and (2) turns the state of the SCH on.
The query form of this command returns the requested level of the SCH.
The optional [:SELected] keyword in this command specifies that the SCH level being set/queried
applies to the current system type. At this time there is only one system type choice,
DIGital2000. Specifying DIGital2000 will have the same effect as using the optional [:SELected]
keyword.
Setting
Range: 0 to -20 dB
Resolution: 0.01 dB
Query
Range: 0 to -20 dB
Resolution: 0.01 dB
*RST Setting
-15.6 dB
Programming Example
OUTPUT 714;"CALL:SCHANNEL:SLEVEL:SELECTED -10"
!Sets the cell’s forward supplemental channel state to on and the level to -10 dB.
Function
Sets/queries the data rate of the currently selected radio configuration.
To find out which radio configuration is currently selected, see
.
Entering a data rate that is not included in the radio configuration’s set of valid entries will cause
the test set to generate an error message.
Setting
Range: See command descriptions for RCONfig1 through RCONfig5.
Query
Range: See command descriptions for RCONfig1 through RCONfig5.
*RST Setting
BPS9600
Programming Example
OUTPUT 714;"CALL:SCHANNEL:DRATE?"
!Queries the data rate for the currently selected radio configuration