8
Maintaining the MMI
Consumables and Parts for the Multimode Inlet
122
Maintaining Your GC
Consumables and Parts for the Multimode Inlet
See the Agilent catalog for consumables and supplies for a more complete listing, or visit the
Agilent Web site for the latest information (
Table 21 Split, splitless, direct, and direct connect inlet liners
Mode
Description
Deactivated
Part number
Split
Low-pressure drop, glass wool, single taper, 870 µL
Yes
5183-4647
Split
Glass wool, 990 µL
No
19251-60540
Split—Manual only
Empty pin and cup, 800 µL
No
18740-80190
Split—Manual only
Packed pin and cup, 800 µL
No
18740-60840
Splitless
Single taper, glass wool, 900 µL
Yes
5062-3587
Splitless
Single taper, no glass wool, 900 µL
Yes
5181-3316
Splitless
Dual taper, no glass wool, 800 µL
Yes
5181-3315
Splitless—Direct inject
2-mm id, quartz, 250 µL
No
18740-80220
Splitless—Direct inject
2-mm id, 250 µL
Yes
5181-8818
Direct inject —Headspace or purge
and trap
1.5-mm id, 140 µL
No
18740-80200
Direct column connect
Single taper, splitless 4-mm id
Yes
G1544-80730
Direct column connect
Dual taper, splitless 4-mm id
Yes
G1544-80700
Table 22 Nuts, ferrules, and hardware for capillary columns
Column id (mm)
Description
Typical use
Part number/quantity
.530
Ferrule, Vespel/graphite, 0.8-mm id
0.45-mm and 0.53-mm capillary columns
5062-3512 (10/pk)
Ferrule, graphite, 1.0-mm id
0.53-mm capillary columns
5080-8773 (10/pk)
Ferrule, graphite, 0.8-mm id
0.53-mm capillary columns
500-2118 (10/pk)
Column nut, finger-tight (for
0.53-mm columns)
Connect column to inlet or detector
5020-8293
.320
Ferrule, Vespel/graphite, 0.5-mm id
0.32-mm capillary columns
5062-3514 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for .100- to
.320-mm columns)
Connect column to inlet or detector
5020-8292
.250
Ferrule, Vespel/graphite, 0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm capillary
columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for .100- to
.320-mm columns)
Connect column to inlet or detector
5020-8292
Summary of Contents for 8890
Page 1: ...Agilent 8890 Gas Chromatograph Maintaining Your Gas Chromatograph GC ...
Page 8: ...8 Maintaining Your GC ...
Page 22: ...2 Removing Covers To Remove the Electronics Cover 22 Maintaining Your GC ...
Page 142: ...8 Maintaining the MMI To Bakeout Contaminants from the MMI 142 Maintaining Your GC ...
Page 178: ...10 Maintaining the VI To Bakeout Contaminants from the VI Inlet 178 Maintaining Your GC ...
Page 208: ...12 Maintaining the TCD To Bakeout Contaminants from the TCD 208 Maintaining Your GC ...
Page 240: ...14 Maintaining the ECD To Bakeout the ECD 240 Maintaining Your GC ...
Page 264: ...16 Maintaining EPC Modules Installing or Replacing Frits in the PCM 264 Maintaining Your GC ...
Page 276: ...17 Maintaining a Valve To Install the Upper Valve Box 276 Maintaining Your GC ...