
18-15
Measure Commands
CGRade:EHEight
Query
:MEASure:CGRade:DCYCle? [<source>]
This query returns the duty cycle of the color graded display.
Returned Format
[:MEASure:CGRade:DCYCle]<value>[,<result_state>]<NL>
<value> is the duty cycle. If SENDvalid is ON, the <result_state> is returned with the mea-
surement result. Refer to
for a list of the result states.
Example
10 OUTPUT 707;”:MEASURE:CGRADE:DCYCle”
CGRade:EHEight
Command
:MEASure:CGRade:EHEight RATio [,{CHANnel<N> | FUNCtion<N> | CGMemory}]
Measures the eye height on the eye diagram of the current color grade display. The data for
color grade display is the same as for gray scale display. If the source is not set, the lowest
numbered signal display that is on will be the source of the measurement.
Mode
Eye mode only.
Query
:MEASure:CGRade:EHEight? RATio [,{CHANnel<N> | FUNCtion<N> | CGMemory}]
Returned Format
[:MEASure:CGRade:EHEight] <eye_height>[,<result_state>]<NL>
If SENDvalid is ON, the <result_state> is returned with the measurement result. Refer to
for a list of the result states.
Example
10 OUTPUT 707;”:SYSTEM:HEADER OFF”
20 OUTPUT 707;”:MEASURE:CGRADE:EHEight?”
CGRade:ERATio
Command
:MEASure:CGRade:ERATio <format> [,{CHANnel<N> | FUNCtion<N> | CGMemory}]
Measures the extinction ratio on the eye diagram of the current color grade display. The dark
level or dc offset of the input channel must have been previously calibrated. The data for
color grade display is the same as for gray scale display. If the source is not set, the lowest
numbered signal display that is on will be the source of the measurement. <format> is {RATio
| DECibel | PERCent}.
Mode
Eye mode only.
Query
:MEASure:CGRade:ERATio? <format> [,{CHANnel<N> | FUNCtion<N> | CGMemory}]
The query returns the extinction ratio of the color grade display.
Returned Format
[:MEASure:CGRade:ERATio] <value>[,<result_state>]<NL>
<value> is the extinction ratio. If SENDvalid is ON, the <result_state> is returned with the
measurement result. Refer to
for a list of the result states.
Example
10 OUTPUT 707;”:SYSTEM:HEADER OFF”
20 OUTPUT 707;”:MEASURE:CGRADE:ERATIO? RATIO”
CGRade:ERFactor
Command
:MEASure:CGRade:ERFactor CHANnel<N>,{ON|OFF}[,<correction_factor>]
Turns on or off the extinction ratio correction and, optionally, to set the correction factor
used when correction is turned on. <N> specifies a channel, where <N> is 1, 2, 3 or 4. Each
channel has its own setting for on or off and for correction factor. <correction_factor> is a
Summary of Contents for 86100A
Page 18: ...1 14 Introduction Status Reporting Figure 1 4 Status Reporting Data Structures...
Page 19: ...1 15 Introduction Status Reporting Status Reporting Data Structures continued...
Page 94: ...2 40 Sample Programs BASIC Programming Examples...
Page 124: ...4 16 Root Level Commands VIEW...
Page 132: ...5 8 System Commands TIME...
Page 140: ...6 8 Acquire Commands SWAVeform RESet...
Page 152: ...7 12 Calibration Commands STATus...
Page 192: ...11 12 Display Commands SSAVer...
Page 202: ...12 10 Function Commands VERTical RANGe...
Page 203: ...13 AREA 13 2 DPRinter 13 2 FACTors 13 3 IMAGe 13 3 PRINters 13 4 Hardcopy Commands...
Page 316: ...21 12 TDR TDT Commands Rev A 05 00 and Below STIMulus...
Page 332: ......