4-12
Programming
*ESE (Event Status Enable)
The Standard Event Status Enable Register is cleared at power-on. The *RST
and *CLS commands do not change the register.
The *ESE query returns the value of the Standard Event Status Enable Regis-
ter.
Usage:
GPIB only
Command Syntax:
*ESE <mask>
Where:
<mask> ::= 0 to 255
Example:
OUTPUT 711;"*ESE 64"
In this example, the *ESE 64 command enables URQ (user request) bit 6 of
the Standard Event Status Enable Register. Therefore, when a front-panel key
is pressed, the ESB (event summary bit) in the Status Byte Register is also
set.
Query Syntax:
*ESE?
Returned Format:
<mask><NL>
Where:
<mask> ::= 0 to 255 (integer–NR1 format)
Table 4-1. Standard Event Status Enable Register
(High–Enables the ERS bit)
Bit
Bit Weight
Enables
7
128
PON – Power On
6
64
URQ – User Request
5
32
CME – Command Error
4
16
EXE – Execution Error
3
8
NOT USED
2
4
QYE – Query Error
Summary of Contents for 86060C Series
Page 1: ...Agilent 86060C Series Lightwave Switches User s Guide ...
Page 6: ......
Page 17: ...1 11 General Information Specifications and Regulatory Information ...
Page 32: ......
Page 50: ......
Page 91: ...5 Spare Channel Replacement Procedure 5 4 Electrostatic Discharge Information 5 7 Servicing ...
Page 102: ......