FINAL
TRIM
SIZE
:
7.5
in
x
9.0
in
P
erforming
Measurements
Creating
Limit
Lines
Indications
of
pass/fail
conditions
Several
indications
of
pass
or
fail
status
are
provided
when
limit
testing
is
on:
A
PASS
or
FAIL
message
is
displayed
at
the
right
of
the
display
.
The
trace
vector
leading
to
any
measured
point
that
is
out
of
limits
is
displayed
in
a
dierent
color
.
It
appears
normal
on
a
or
plot.
The
limit
fail
beeper
sounds
if
it
is
turned
on.
An
asterisk
*
is
shown
next
to
any
listed
point
that
is
out
of
limits
.
A
bit
is
set
in
the
HP-IB
status
byte
.
N
O
T
E
Limits
are
checked
only
at
the
actual
measured
data
points.
If
the
point
density
is
insucient,
a
device
can
be
out
of
specication
without
displa
ying
FAIL .
Be
sure
to
specify
a
suitable
number
of
measurement
points.
Limit
lines
can
be
shifted
Limit
lines
can
be
oset
horizontally
or
vertically
.
This
is
useful
for
changing
the
limits
to
correspond
with
a
change
in
the
test
setup
,
or
for
device
specications
that
dier
in
stimulus
or
amplitude
.
It
can
also
be
used
to
move
the
limit
lines
away
from
the
data
trace
temporarily
for
visual
examination
of
trace
detail.
N
O
T
E
The
three
oset
ke
ys
(
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
AMPLITUDE
OFFSET
,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MARKER
!
AMP.OFF.
,
and
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
POSITION
OFFSET
)
shift
the
limit
segments
but
do
not
change
the
limit
values
in
the
table
.
If
the
limit
segments
look
out
of
place
,
check
to
see
if
the
y
have
been
shifted
in
position
or
amplitude
.
3-22
Summary of Contents for 8504B
Page 2: ...FINAL TRIM SIZE 7 5 in x 9 0 in User s Guide Agilent 8504B Precision Re ectometer ...
Page 13: ...FINAL TRIM SIZE 7 5 in x 9 0 in ...
Page 17: ...FINAL TRIM SIZE 7 5 in x 9 0 in Contents ...
Page 18: ...FINAL TRIM SIZE 7 5 in x 9 0 in 1 Installing ...
Page 47: ...FINAL TRIM SIZE 7 5 in x 9 0 in Installing ...
Page 48: ...FINAL TRIM SIZE 7 5 in x 9 0 in 2 Performing Guided Setups and Calibrations ...
Page 78: ...FINAL TRIM SIZE 7 5 in x 9 0 in 3 Performing Measurements ...
Page 128: ...FINAL TRIM SIZE 7 5 in x 9 0 in 4 Programming ...
Page 138: ...FINAL TRIM SIZE 7 5 in x 9 0 in Programming StatusReportingRegisters 4 11 ...
Page 187: ...FINAL TRIM SIZE 7 5 in x 9 0 in Programming ...
Page 188: ...FINAL TRIM SIZE 7 5 in x 9 0 in 5 Reference ...
Page 191: ...FINAL TRIM SIZE 7 5 in x 9 0 in Reference MenuMaps 5 4 ...
Page 192: ...FINAL TRIM SIZE 7 5 in x 9 0 in Reference MenuMaps 5 5 ...
Page 193: ...FINAL TRIM SIZE 7 5 in x 9 0 in Reference MenuMaps 5 6 ...
Page 194: ...FINAL TRIM SIZE 7 5 in x 9 0 in Reference MenuMaps 5 7 ...
Page 195: ...FINAL TRIM SIZE 7 5 in x 9 0 in Reference MenuMaps 5 8 ...
Page 196: ...FINAL TRIM SIZE 7 5 in x 9 0 in Reference MenuMaps 5 9 ...
Page 197: ...FINAL TRIM SIZE 7 5 in x 9 0 in Reference 5 10 ...
Page 239: ...FINAL TRIM SIZE 7 5 in x 9 0 in Reference Block Diagram 5 52 ...
Page 243: ...FINAL TRIM SIZE 7 5 in x 9 0 in Reference Line Power Cables 5 56 ...
Page 244: ...FINAL TRIM SIZE 7 5 in x 9 0 in 6 Speci cations and Regulatory Information ...
Page 260: ...FINAL TRIM SIZE 7 5 in x 9 0 in Speci cations andRegulatoryInformation 6 17 ...
Page 261: ...FINAL TRIM SIZE 7 5 in x 9 0 in Speci cationsandRegulatoryInformation ...
Page 262: ...FINAL TRIM SIZE 7 5 in x 9 0 in 7 Error Messages ...
Page 274: ...FINAL TRIM SIZE 7 5 in x 9 0 in Index ...
Page 295: ...FINAL TRIM SIZE 7 5 in x 9 0 in ...