25
Chapter 1, General Information
Front Panel
4. RF IN/OUT
Connects to the transmit/receive antenna port of a radio.
(Connector type: Type N (F))
CAUTION:
The maximum allowable average power to the RF IN/OUT port depends on the unit-under-
test as follows. Use an external attenuator if you are uncertain.
Subscriber Unit Test
Single carrier TDMA and FM:
10 Watts
CDMA:
5 Watts
Base Station Test
Single carrier TDMA and FM:
10 Watts
CDMA:
1 Watt
CAUTION:
Peak instantaneous signals greater than 30 volts will damage internal circuitry.
5. RF OUT only
Connects to the receive antenna port of a radio. (Connector type: Type N (F))
CAUTION:
Do not input a continuous signal greater than +23 dBm (200 mW). Doing so may damage
internal circuits.