Overcome Battery Powered 
Device Testing Challenges

Digital communications devices 
and digital battery powered devices
present a unique testing challenge:
they draw rapid pulses of current.
By offering superior transient 
performance, unmatched in the
marketplace, the Agilent Mobile
Communications DC Sources 
dramatically reduce the transient
voltage drop due to pulse loading
characteristics of digital communi-
cations devices. The Agilent Mobile
Communications DC Sources enable
you to maximize test throughput by
minimizing test interruption due to
false trigger of device low voltage
shutdown.

Dynamic Measurement Capabilities

The Agilent Mobile Communications
DC Sources offer a built-in advanced
measurement system to accurately
measure battery current drains
when the device operates in differ-
ent modes (such as talk mode, active
mode, standby mode, and off/sleep
mode).  Measurements made during
these modes are critical for ensuring
that your devices are operating
properly and that you are getting
the most out of the battery.

Simulate both Main Battery and Charger

Single output models are recom-
mended when you need to provide
power as a replacement to your 

Application Specific DC Power Supplies tailored solutions for specific needs

Specifications

(at 0

˚

to 55

˚

C unless 

otherwise specified)

66309B/D 66311B  66319B/D 66321B/D 66332A

66332A-
J01

Special Order
Option

More detailed specifications at www.agilent.com/find/66300

81

Ideal for testing wireless and battery powered devices

Several times improvement in measurement throughput over general purpose DC sources

Superior output transient performance with short or long load leads (up to 6 meters)

Dynamic measurement system for accurate battery current drain measurement

New easy-to-use Graphical User Interface and analysis tools for bench top use

Mobile Communications DC Sources
40-100 W 

Number of outputs

2

1

2

1

1

1

GPIB

Yes

Yes

Yes

Yes

Yes

Yes

Output ratings 

Voltage 

0 to 15 V 

0 to 15 V 

0 to 15 V 

0 to 15 V 

0 to 20 V

0 to 30 V

Current 

0 to 3 A 

0 to 3 A 

0 to 3 A 

0 to 3 A 

0 to 5 A

0 to 3.3 A

Peak current for up to 7 ms 

5 A 

5 A 

5 A 

5 A 

5 A

3.3 A

Programming accuracy 
at 25°C ±5°C (% of setting plus fixed)

Voltage 

0.05%+ 

10 mV 

10 mV 

10 mV 

10 mV 

10 mV

15 mV

+Current 

0.05%+ 

1.33 mA 

1.33 mA 

1.33 mA 

1.33 mA 

2 mA

2 mA

Ripple and Noise (20 Hz to 20 MHz) 

Voltage

rms 

1 mV 

1 mV 

1 mV 

1 mV 

0.3 mV

0.5 mV

peak-to-peak

6 mV

6 mV

6 mV

6 mV

3 mV

5 mV

Current 

rms

2 mA 

2 mA 

2 mA 

2 mA 

2 mA

2 mA

DC measurement accuracy

Voltage 

0.03%+ 

5 mV 

5 mV 

5 mV 

5 mV 

3 mV

5 mV

+20 mA to + rated current  0.2%+ 

0.5 mA

2

0.5 mA

2

0.5 mA

0.5 mA

-20 mA to - rated current  0.2%+ 

1.1 mA 

1.1 mA 

1.1 mA

1.1 mA

-3 A to + 5 A 

0.2% 

0.5 mA

2

0.5 mA

2

-1 A to + 1 A 

0.1% 

0.2 mA 

0.2 mA

-20 mA to + 20 mA range  0.1%+

2.5 µA 

2.5 µA 

2.5 µA 

2.5 µA 

2.5 µA

2.5 µA

Dynamic measurement system

Buffer size 

4096 points  4096 points  4096 points  4096 points  4096 points 4096 points

Sampling interval 

15 µs - 

15 µs - 

15 µs - 

15 µs - 

15 µs - 

15 µs - 

31,200 s 

31,200 s 

31,200 s 

31,200 s 

31,200 s

31,200 s 

Transient response time 

<35 µs

3

<35 µs

3

<20 µs

3

<20 µs 

<100 µs

4

<100 µs

4

Transient voltage dip

70 mV 

70 mV 

40 mV 

40 mV 

500 mV

650 mV

(typical with up to 15 feet 
22 AWG wiring)

Programmable output resistance

Range —-

-40 

m

to -40 

m

to —

+1 

+1 

Programming accuracy 

0.5% + 

0.5% + 

2 m

2 m

Resolution —

m

1 m

66319B/D, 66321B/D

Summary of Contents for 66309B

Page 1: ...ment throughput over general purpose DC sources Superior output transient performance with short or long load leads up to 6 meters Dynamic measurement system for accurate battery current drain measure...

Page 2: ...o 25 to 25 to 25 Vdc 25 Vdc 25 Vdc DC readback accuracy 0 04 0 04 0 04 at 25 C 5 C 5 mV 5 mV 5 mV AC DC readback accuracy 1 1 1 at 25 C 5 C with DC plus 5 mV 5 mV 5 mV a sinewave input 25 mV rms 60 Hz...

Page 3: ...output voltage is 2 ms 400 s in fast mode The output voltage change settles within 1 LSB 0 025 x full scale voltage of final value in 6 ms 2 ms in fast mode For 66311B 66321B D 66309B D output 1 6631...

Page 4: ...o 253 Vac 47 to 63 Hz Opt 004 Make Hi Compensation Mode as default setting Opt 007 Extra 5 pin output connectors 2 x p n 0360 2604 Opt 020 Front panel Binding Posts 66332A only Opt UJ0 No front panel...