Chapter 7
85
Sorting Based on Measured Result (Comparator Function)
Rejecting Excessively Low Measured Results (Low C reject function)
7.
So
rting
Ba
se
d on
M
eas
ur
ed
Res
u
lt
(C
ompar
ator
F
u
n
c
tion
)
Rejecting Excessively Low Measured Results (Low C reject
function)
Turning ON/OFF Low C reject function
To turn ON/OFF the Low C reject function, use the following command.
•
You can detect an excessively low (equal to or less than the preset boundary value)
measured result of the primary parameter value (Cp or Cs) as Low C (abnormal
measurement status) by turning ON the Low C reject function.
NOTE
When the comparator function is ON, the sorting judgment is performed normally even if
Low C is detected. However, the sorting judgment result displayed on the screen is LOWC
and, on the handler interface, the /LOW_C_REJECT signal becomes active (LOW) in
addition to the sorting judgment signal.
Setting limit (range boundary values) of Low C reject function
To set the limit (boundary values of the range in which Low C is detected) of the Low C
reject function, use the following command.
•