![AGI GGH-8361LO Installation, Operation, And Parts Manual Download Page 46](http://html1.mh-extra.com/html/agi/ggh-8361lo/ggh-8361lo_installation-operation-and-parts-manual_2867017046.webp)
46
GNA-2538 R0
8.3. Electrical Schematics
Important
When installing new wires, always replace wires with original type and/or an equivalent wire type.
ON/OFF
THERMOSTAT
INDICATOR
LIGHT
G
G
11
601-1938
HEATER WIRING SCHEMATIC ON/OFF CYCLING MODELS
MODELS:
GGH-8371LO GGH-8372LO GGH-8371NO GGH-8372NO GGH-8371VO GGH-8372VO GGH-8361LO GGH-8362LO GGH-8361NO GGH-8362NO
HEATER MUST BE
INTERLOCKED TO FAN
POWER FROM FAN
VAPOR HIGH LIMIT SWITCH
(160F)
ONLY USED ON LIQUID PROPANE
WIRE
SPARK
TO IGNITOR
TO FLAME PROBE
1.5AMP FUSE
ON/OFF SOLENOID VALVE 2
ON/OFF SOLENOID VALVE 1
LIQUID
SOLENOID
VALVE
S
S
S
COM
NC
NO
AIR SWITCH
TOGGLE SWITCH
ON OFF
TEST
BURNER HIGH LIMIT SWITCH
(160F)
TRANSITION HIGH
LIMIT SWITCH
(200F)
3AMP FUSE
120VAC
0VAC
GROUND
L2 (Neutral)
L1 (LINE)
S1
B.
GND
L1
L2
V2
V1
NC
D1
FENWAL CONTROL
35-705706-115
10
10
9
9
8
7
6
5
4
3
2
1
ONLY USED ON
LIQUID PROPANE
B
C
A
PENN
EMERSON
B
C
A
LC
LNE
LNO
LN
NEUT
LOAD
CONTROLLER HOOKUP
INFORMATION
AXIAL FAN HEATER – LP AND NG-FIRED HEATER