background image

Hadley Wood Stove

(Smoke Exempt)

INSTALLATION AND OPERATING INSTRUCTIONS

This appliance is hot while in operation and retains its heat for a long period of time after use.
Children, aged or infirm persons should be supervised at all times and should not be allowed
to touch the hot working surfaces while in use or until the appliance has thoroughly cooled.

When using the stove in situations where children, aged and/or infirm persons are 
present a fireguard must be used to prevent accidental contact with the stove.  The fireguard
should be manufactured in accordance with BS 8423:2002.

Summary of Contents for Hadley

Page 1: ...irm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 ...

Page 2: ...ombustibles 5 12 Safe Distance from Chimneys from Flammable materials 5 13 Stove Dimensions 6 14 Technical Data 6 15 Air Controls 7 16 Recommended Fuels 7 17 Refuelling 7 Refuelling onto a low firebed 7 Fuel overloading 7 Operation with door left open 7 18 Dampers Air Controls Left Open 7 19 De Ashing 7 20 Maintenance 8 21 Chimney Cleaning 8 22 Important Notes 8 23 Lighting 9 24 Fire Safety 9 25 C...

Page 3: ...ETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at www hetas co uk The installation must be completed in accordance with current National and European Standards and Local Codes It should be noted that the requirements and these publications may be superseded during the life of this manual IMPORTANT WARNING This stove must not be inst...

Page 4: ...chimney termination must be free of any obstructions see requirements under Approved Document J avail able to download at www planningportal gov uk For guidance when installing new chimney systems or relining existing chimneys please refer to BS EN 15287 DOWN DRAUGHTS However well designed constructed and positioned the satisfactory performance of the flue can be adversely affected by down draught...

Page 5: ...uous duct across the cavity The duct should be installed in such a manner as not to impair the weather resistance of the cavity Joints between air vents and outside walls should be sealed to prevent the ingress of mois ture Existing air vents should be of the correct size and unobstructed for the appliance in use If there is anextraction fan fitted in adjacent rooms where this appliance is fitted ...

Page 6: ... fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user what to do should smoke or fumes be emitted from the stove The customer should be warned to use a fire guard to BS 8423 2002 in the presence of children aged and or infirm persons LOCATION There are several conditions to be considered in selecting a location for your stove A Allowanc...

Page 7: ...ce with BS EN 13240 NOTE A suitable chimney minimum profile chimney draft tightness etc is a basic condition for the proper functioning of fireplace stoves See professional advice before installing the stove Chimney values are included in the attached technical sheet A smoke shutter or a draft regulator should be installed for chimneys with too strong a draft Such a draft can cause problems during...

Page 8: ...ately 3 minutes allowing the new refuel charge to establish combustion before adjusting the air control to the desired setting Refuelling on to a low fire bed If there is insufficient burning material in the firebed to light a new fuel charge excessive smoke emis sion can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite ...

Page 9: ...lly dangerous and must not be tolerated If fume emission does persist then the following immediate action should be taken a Open doors and windows to ventilate room and then leave the premises b Let the fire out c Check for flue or chimney blockage and clean if required d Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected If necessary seek exp...

Page 10: ... Before lighting the stove check with the installer that the installation work and commissioning checks described in the installation instructions have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the installer should demonstrate how to operate the stove correctly WARNING The paint on t...

Page 11: ...removed 2 Lift and tilt the side bricks No 2 to remove them 3 Remove the back brick 4 Bricks must be replaced in reverse order GLASS 1 How to clean The glass will clean itself when there is sufficient heat generated by burning fuel If a build up of creosote occurs on the glass it may be due to draft conditions poor quality fuel or very slow burning for a long time Only clean glass when the stove i...

Page 12: ...11 EXPLODED VIEW ...

Page 13: ...CSN_021702A_8_4 28 CSN_021103_M8X20 29 CSN_021103_M8X20 30 CSN_021702A_8_4 31 4901_000_025_24 32 CSN_021702A_8_4 33 CSN_021401_M8 Exp View No Part Code 34 003A_0000_031 35 CSN_021103_M6X12 36 CSN_021745_6_4 37 082A_0600_001 38 026A_2010_002 39 026A_2010_102 40 026A_2010_022 41 026A_2010_012 42 SAMOT_BOCNI_500_140_RMT 43 026A_2010_032 44 082A_2000_001 45 082A_2000_011 46 CSN_021103_M6X14 47 CSN0217...

Page 14: ...ng Replace the grate and do not allow ash pan to overfill Operation with the ash door open While the stove is in operation the door should be closed Burning non approved fuel Burn seasoned wood only Glass Sooting Up Air wash not working Open the air wash control Moissture content of fuel too high Ensure fuel is sufficiently dry Insufficient flue draught Seek professional chimney advice Air control...

Page 15: ...ve soot Smells From Stove Installation Final cure of the painted surfaces This odour is unpleasant but not toxic It is best advised to ventilate the room and leave unoccupied Incorrect sealant used All flue Joints must be sealed with fire cement only Insufficent flue draught Seek professional chimney advice Water In Base Of Stove Condensation on light up It is acceptable to have a little condensa ...

Page 16: ...AGA Station Road Ketley Telford Shropshire TF1 5AQ UK Rev 002 DP28 04 15 N00645AXX 15 ...