16
8.
Using the stay rod nut adjusting tool, carefully lower the top plate adjusting nuts until the top
plate sits at the required height, making sure that the top sits level and matches the height of
the AGA eR7. (
Fig. 3.9
).
For servicing requirement, top plate should be removed by raising adjusters approximately 5mm, the
top plate can now be removed easily without causing damage to the enamelled surfaces.
When removing the top plate, the switch wiring harness should be disconnected from the main
wiring harness at the connection point located at the front left hand side of the appliance, beneath
the formex cover sheet.
DESN 516555
9.
Fit the handrail bracket over the fixing stud located on the top plate. Lock into position by
tightening the grub screw nearest the appliance. (
Fig. 3.10
).
DESN 516883
Fig. 3.9
Fig. 3.10
Summary of Contents for eR7 100-3