Troubleshooting
– German –
28
ÖWWG 3
9 Troubleshooting
The product is safety-related equipment.
Any malfunctions that cannot be removed by means of the measures
described in this chapter may only be repaired by the manufacturer.
Problem
Possible reason
Repair
Green LED is not
on
No mains voltage
Apply mains volt-
age
Mains cable is not
properly connected
Properly connect
the mains cable
Mains fuse defective
Replace the mains
fuse
Flat cable not con-
nected to printed cir-
cuit board
Connect the flat ca-
ble to the printed
circuit board
Red LED is on
Alarm: Probe sub-
merged in liquid
Remove cause of
alarm
Reset key pressed
Press Reset key
again
Probe not connected
Connect probe
Red LED is al-
ways on, even if
the probe is not
submerged in liq-
uid
Probe fuse defective
Replace the probe
fuse
Line interruption be-
tween control unit
and probe
Check the line
Pressing the Test
key has no effect
Product defective
Replace the prod-
uct
Other
malfunctions
–
Contact the AF-
RISO service hot-
line
Summary of Contents for OWWG 3
Page 32: ... Deutsch Anhang ÖWWG 3 31 16 Anhang 16 1 EU Konformitätserklärung ...
Page 33: ...Anhang Deutsch 32 ÖWWG 3 16 2 Zulassungsunterlagen ...
Page 34: ... Deutsch Anhang ÖWWG 3 33 ...
Page 35: ...Anhang Deutsch 34 ÖWWG 3 ...
Page 36: ... Deutsch Anhang ÖWWG 3 35 ...
Page 37: ...Anhang Deutsch 36 ÖWWG 3 ...
Page 38: ... Deutsch Anhang ÖWWG 3 37 ...
Page 39: ...Anhang Deutsch 38 ÖWWG 3 ...
Page 70: ... German Appendix ÖWWG 3 31 16 Appendix 16 1 EU Declaration of Conformity ...
Page 101: ... Français Annexe ÖWWG 3 31 16 Annexe 16 1 Déclaration de conformité UE ...
Page 135: ...Aneks niemiecki 34 ÖWWG 3 16 Aneks 16 1 Deklaracja zgodności UE ...