Maintenance
– German –
26
ÖWWG 3
8 Maintenance
The type of inspection and the intervals during the period mentioned
are the responsibility of the owner/operator.
8.1
Maintenance intervals
When
Activity
Monthly
Perform visual inspection for damage,
corrosion and pollution.
Twice a year
Perform a function test, see chapter 6.8,
page 24.
Annually and dur-
ing commissioning
After repairs
Perform a function test, see chapter 6.8,
page 24.
Verify that the installation requirements
are complied with and perform function
test (see chapter 6.8, page 24).
Document the test results.
At least every ten
years or after
damage due to
media
Replace probe, see chapter 6.1, page 17.