![Afriso EURO-INDEX DIT 10 Operating Instructions Manual Download Page 31](http://html1.mh-extra.com/html/afriso-euro-index/dit-10/dit-10_operating-instructions-manual_2864880031.webp)
– English –
Transport and storage
DIT 10
31
5
Transport and storage
CAUTION
Damage to the product due to improper transport.
Do not throw or drop the product.
CAUTION
Damage to the product due to improper storage.
Protect the product from shock when storing it.
Store the product in a clean and dry environment.
Only store the product within the permissible temperature
range.
6
Mounting and commissioning
6.1
Determining the tank data
You must determine the tank data before installing the tank contents
indicator DIT 10. Document the tank data you have determined in the
form below.
Tank shape
Determine the code for the tank shape from the table below:
Example linear indication: tank shape code 1.
Tank
shape
code
Tank shape
Description
1
Linear tank
Rectangular tanks, upright
cylinders, steel tanks welded
in the basement and all other
linear measuring applications
2
Cylindrical tank
Vertically mounted cylinders
3
Spherical tank
Spherical tank
4
Plastic battery tank
Plastic battery type tanks with
straps or bulges
5
Oval tank
Oval basement tanks, for ex-
ample, glass-fibre reinforced