22
Fiber optic test cables are necessary to connect ROGUE Tester to the fiber under test (FUT) . Test
cables must have the same core and cladding size as the FUT . The connector at one end of the
test cable must mate with the appropriate optical port on the ROGUE Tester . The connector on the
other end must mate with the fiber optic link under test .
Launch and Receive cables are required for OTDR testing to measure the insertion loss and
reflectance of the near-end and far-end connectors respectively, of the fiber link being tested . AFL
Fiber Rings may be used as Launch and Receive cables . Fiber Rings with a variety of lengths and
connector styles are available from AFL .
General
Recommended Accessories
Cleaning Tips
Cleaning Connectors on Test Cables and Fiber Under Test
It is important to keep connector end-faces on test cables and on the fiber under test clean, to
ensure accurate measurements and operation .
IMPORTANT!
Inspect optical connectors after cleaning to ensure cleaning was successful and to
verify the end-face is not damaged (cracked, pitted, etc .) .
CAUTION!
Never view a live fiber . Laser radiation is harmful to eyes .
Follow your company’s approved cleaning procedures .
AFL recommends cleaning test cables using a Cletop cassette cleaner or a One-Click Cleaner .
CAUTION!
Before conducting the following procedures be sure to have the OTDR turned OFF .
Cleaning the OTDR and VFL optical ports without removing the adapters
AFL One-Click Cleaner method
•
Remove the protective dust cover from the tip of the One-Click Cleaner .
•
Insert the tip of the One-Click Cleaner into the optical port adapter and gently press the body
of the One-Click Cleaner until an audible “click” is heard .
•
Remove the One-Click Cleaner .
AFL FCC2 fluid and CCT stick method
•
Lean a can of FCC2 back (30°), press the button on FCC2 to fill the well .
•
Dip a CCT stick into the well of the FCC2 to dampen the tip with optical cleaning fluid .
•
Place the damp tip over the ferrule to be cleaned .
•
Rotate the tip clockwise 10 revolutions while applying varying pressure to create a gentle
pumping action where the tip contacts the ferrule .
•
Discard the CCT stick after using both tips .