background image

Installation Guide

H-Series 7RU 
Housing

Series

Summary of Contents for H-Series 7RU Housing

Page 1: ...Installation Guide H Series 7RU Housing Series ...

Page 2: ...rrange for an eye examination immediately General Precautions Personnel must be thoroughly familiarized with all applicable Occupational Health and Safety OH S regulations local regulations and your company safety practices and policies Warning To reduce the chance of accidental injury Before work begins all personnel must be thoroughly familiar with the operation of all equipment and procedures t...

Page 3: ...3 H Series 7RU Housing AFL Hyperscale All rights reserved Series Component Overview ...

Page 4: ...02 Door Label Cross Head Screwdriver 250 μm Wrapping Tube Cable WTC with SpiderWeb Ribbon SWR Up to 24 H Series Cassettes MPO MicroCable Patch Assembly Single Jacket 3mm OD LC Premium Uniboot Patch Cords Reversible Polarity M6 x 16mm Screw and Nuts 4pcs MicroCable Assemblies 2mm Tails What You Will Need Related Products Data Center Patch Cords 03 Housing Number Label ...

Page 5: ...ights reserved Series H Series Cassette Types H Series Cassette Types MPO LC Cassette BASE 12 24f 24f Pass Through Cassette MPO Cassette BASE 12 144f Blank Plate 24f LC Ribbon Single Splice Cassette 24f Splice Only Cassette Splice Only Cassette ...

Page 6: ... Hyperscale All rights reserved Series Mounting the Housing Install the housing in the rack using the M6 x 16mm screws 1 Open the front door up to a 135º angle and place the label on the inside of the door 2 ...

Page 7: ... the snap rivets of the cassette with the holes to the top and bottom of the housing ensuring the cassette is straight Make sure the adapter or cable gland for cable entry is at the top of the cassette and outbound adapters for patch cords are at the bottom before being installed into the housing 3 Install the remainder of the cassettes 4 ...

Page 8: ...e All rights reserved Series Loading the Cables Incoming cable can enter from the left or right of the top fiber management bar 5 Left hand entry for incoming inbound cable Right hand entry for incoming inbound cable ...

Page 9: ...ing is suitable for 2mm uniboot round duplex 3mm MPO cable jackets or LC short boot 18mm simplex patch cords with 2mm cable 6a Patch cords can be dressed to exit to the left or right side of the bottom fiber management bar This configuration is suitable for use with LCR Uniboot round duplex 2mm cable or LC short boot 18mm simplex patch cords with 2mm cable 6b One side connection Connecting both si...

Page 10: ...e in position proceed to address the cable to the correct slot positions in order Once complete ensure there is enough cable to proceed with the splicing Start to patch from the bottom of the cassette to the top 7b Loading the Cables NOTE It is recommended to use LCR Uniboot round duplex 2mm cable or 3mm MPO cables when patching the front of the unit One slot per two cassettes One slot per two cas...

Page 11: ...quired Once installed screw the cassette closed install into the housing and patch from the bottom of the cassette to the top Note Assemblies not included with cassette 7c MPO Cassette BASE 12 144f H Series Housing can accommodate up to 12 MPO BASE 12 144f Cassettes Start to patch from the bottom of the cassette to the top following indications at the front of the cassette Cassette can be used wit...

Page 12: ...elow MPO LC Cassette BASE 12 24f and Blank Plate Installation procedure for a blank plate is the same as the cassette If the number of cassettes required does not fill all the positions in the housing we recommend adding blank plates for the remaining spaces Start to patch from the bottom of the cassette to the top 7e ...

Page 13: ...o secure in the holders as shown above 4 Separate the fibers in the incoming cable to match the pigtail bundle and proceed to splice 5 Once complete coil the first bundle in the cassette clockwise and secure the splice protector in the bottom splice holder position 2 6 Repeat the process anti clockwise for the second bundle and secure the splice protector in the top splice holder position 1 7 Clos...

Page 14: ...g the gland We recommend feeding up to 1 5 meters of cable 3 Strip the cable Leave up to 30mm of aramid yarn to secure in the holders as shown above 4 Separate the fibers in the incoming cable to match the pigtail bundle and proceed to splice as per manufacturer s guidelines For ribbon fibers identify the first and second ribbons before splicing 5 Once complete coil the first bundle in the cassett...

Page 15: ... All rights reserved Series For single splice cassette load and splice the pigtails as illustrated above Close housing door once installation is complete 8c Ribbon Single Splice Cassettes Magnet Magnet Slot Bracket Complete installation 8d ...

Page 16: ...Thank you for choosing AFL Hyperscale AFLHSHS7RUH270820 www aflhyperscale com AFL Hyperscale reserves the right to make changes in this Installation Guide without notice ...

Reviews: