background image

6

EN – Instructions for use

Permissible use

The thermostat is used for regulating the room 
temperature or the temperature of the radia-
tor, for e.g. for warming towels, in conjunction 
with an electrical heating element in stationa-
ry radiators.
Any other use is contrary to its intended pur-
pose and therefore not permissible.

 

Safety instructions

 

Do not use the device before complete and 

proper installation.

 WARNING 

Danger  of  death  from  electric 
shocks! 

 

Do not operate the unit if the 
connection cable is damaged. 

If  the  connection  cable  is  damaged,  then  it 
must  be  replaced  by  the  manufacturer,  the 

manufacturer's  customer  service  or  persons 
with  comparable  qualifications  to  prevent  a 

hazardous situation.

 WARNING 

Risk of burns! Some parts of the 
radiator may be very hot. 

 

Supervise children so that they 
do not play with the device. 

 

Observe the applicable instruc

-

tion manuals of the heating el-
ement and the radiator. 

The device may be used by persons 

with  limited  physical,  sensory  and 
mental abilities or by persons with 
little  experience  and  knowledge 

as  well  as  children  above  8  years 
under  supervision  or  they  are  in

-

structed regarding the safe use of 

the device and understand the risk 

resulting therefrom.

Children less than 3 years are to be 
kept  away  from  the  device  unless 

they are monitored continuously.

Children  above  3  years  and  less 
than  8  years  may  only  switch  on 
and  off  the  device  under  above 
mentioned  conditions,  provided 
the device is placed or installed in 

its normal position. 

Children  above  3  years  and  less 
than  8  years  may  not  insert  the 

connector in the socket, clean the 

device and also not carry out main

-

tenance by the user. 

 

Cleaning

 

Disconnect the device from the power sup

-

ply before cleaning or maintenance.

 

Use  only  mild,  non-abrasive  cleansing 

agents.

Complaint

 

Contact your local dealer.

Installation and repairs

 

Have the installation and repairs performed 

by  a  specialized  tradesman  so  that  your 
claims under warranty are not forfeited. 

Disposal

 

Dispose off the unit in the sepa-
rate collection for electrical and 

electronic devices. Observe local 

regulations.

Summary of Contents for Arbonia FKS Series

Page 1: ...stat FKS d ambiance pour l l ment chauf fant lectrique raccordement connecteur plat 2013 08 6912002 AKP Arbonia AG Amriswilerstrasse 50 CH 9320 Arbon T 41 71 447 47 47 F 41 71 447 48 47 www arbonia ch...

Page 2: ...gen F higkeiten oder mangelnder Erfahrung und Wissen sowie Kindern ab 8 Jah ren und dar ber benutzt werden wenn sie beaufsichtigt oder bez g lich des sicheren Gebrauchs des Ge r tes unterwiesen wurden...

Page 3: ...utschland DIN VDE 0100 701 beachten Dar ber hinaus alle rtlichen Vorschriften beachten Bei der Installation eine bauseitige Fehler stromschutzeinrichtung vorsehen Ausl se grenze kleiner gleich 30 mA B...

Page 4: ...ch tzt sind Steckdosen d rfen nur au erhalb der Schutzbereiche montiert werden Hinweis Die Montage der Produkte im Schutzbereich 1 ist vom Hersteller nicht zu gelassen Folgende Produkte nur im Schutzb...

Page 5: ...egulierung der Temperatur des Heizk rpers gew nscht z B weil die Raum temperatur ber eine Fl chenheizung geregelt wird folgende Schritte ausf hren Ger t ausschalten Schalter Ein Aus 1 auf 0 stellen Te...

Page 6: ...sons with limited physical sensory and mental abilities or by persons with little experience and knowledge as well as children above 8 years under supervision or they are in structed regarding the saf...

Page 7: ...erature controller 2 The position on the scale 3 indicates the antifreeze setup Boost mode In the boost mode regardless of the set tem perature level the heating element heats con tinuously for 60 min...

Page 8: ...an isolator in accordance with the local provisions for mains disconnec tion Operate the device only with the approved voltage see typeplate Store and transport the device only in the protective pack...

Page 9: ...he thermostat and push the housing of the thermostat until the end on the base of the heating element Align the thermostat see Fig C7 Press housing against the base of the hea ting element and hand ti...

Page 10: ...uito dal produttore dal suo servizio di assistenza clienti o da persone aventi le stesse qualifiche per evitare cos una situazione di pericolo ATTENZIONE Pericolo di ustioni Alcune parti del radiatore...

Page 11: ...ne costante il livello della temperatura attraverso l accensione e lo spegnimento della barra ter mica Sul regolatore di temperatura 2 im postare la temperatura ambiente desidera ta o il livello di te...

Page 12: ...posa fissa installare il dispositivo di sezio namento secondo le disposizioni locali rela tive al dispositivo per la separazione di rete Far funzionare l apparecchio solo con la tensione consentita v...

Page 13: ...barra termica vedere fig C6 Reinserire i conduttori collegati nell involucro del termostato e spingere l involucro del termostato fino alla battuta sulla base della barra termica Allineare il termosta...

Page 14: ...ent est en dommag Si le c ble de raccordement est endommag il doit tre remplac par le fabricant son ser vice apr s vente ou une personne disposant de qualification comparable afin d viter toute situat...

Page 15: ...de Confort le thermostat maintient la temp rature un niveau constant par allu mage et extinction de l l ment chauffant La temp rature ambiante souhait e ou le niveau de temp rature du radiateur souha...

Page 16: ...l installation lectrique fixe monter un disjoncteur conform ment aux prescriptions locales d quipement pour l isolation du r seau N exploiter l appareil qu la tension admis sible voir la plaque signa...

Page 17: ...Placer une bague de recouvrement adapt e sur le bo tier du thermostat voir fig C4 C5 Raccorder les douilles du connecteur plat des conducteurs de raccordement aux con necteurs plats sur l l ment chauf...

Page 18: ...e de fonctionnement R gulati on de temp rature ambiante 1 mode de fonctionnement Chauffage de serviettes T moin du mode de fonctionnement para m tr Maintenir la touche Boost 4 enfonc e pendant 10 seco...

Page 19: ...19 C2 C3 6 mm 9 mm 28 mm C4 2x 1 5 C1 1 0 2 2 1 0 A B2 B1...

Page 20: ...20 C6 C5 C7 0 5 Nm 1 5 C8 D2 1 1 2 D3 D4 1 1 2 1 5 TX 10 D1 1 2 3 180...

Reviews: