Afag PSG 1 Operating Instructions Manual Download Page 16

 

 

Release:  1.1 

2011-08-06 

Page 15 

6

 

Maintenance instructions 

6.1

 

Troubleshooting and fault repair 

 

Fault: 

Fault repair 

Appliance not working 

Check the mains voltage, check the fuses and 
replace if necessary. 

Check  the  control  signals  and  reset  to  factory 
settings,  if  necessary  (see  chapter  5.2  Set-
tings)
 

Conveyor not working 

Check the mains frequency (50/60 Hz). 

Check  whether  the  oscillation  frequency  was 
correctly  adjusted,  reset  to  factory  settings,  if 
necessary (see chapter 5.2 Settings) 

 

 

 

 

Summary of Contents for PSG 1

Page 1: ...Controller PSG 1 Translation of original operating instruction Copyright by Afag GmbH ...

Page 2: ...Release 1 1 2011 08 06 Page 1 This operation instruction applies to Type Order number Controller PSG 1 230 V 50 60 Hz 50211833 Version of documentation BA_PSG1_R1 1_E Release 1 1 Datum 2011 08 06 ...

Page 3: ...ion 5 2 3 Appropriate use 5 3 Description of the device 6 3 1 General 6 3 2 Technical data 7 4 Assembly instructions 8 4 1 Installing the unit 8 4 2 Installation 8 4 3 Connection possibilities 8 5 Operating instructions 10 5 1 Menu operation 10 5 2 Settings 11 6 Maintenance instructions 15 6 1 Troubleshooting and fault repair 15 7 Address for orders 16 8 Disposal 16 ...

Page 4: ...ic safety and health requirements of the EMC Directive 2004 108 EC The product also complies with the following applied harmonised standards Product standard for interference immunity EN 61000 6 2 EN 61000 6 4 Upon request the manufacturer undertakes to transmit technical documents electronically to national authorities if requested City Date Company Afag GmbH Amberg 6 September 2010 First name la...

Page 5: ...es an immediate threatening danger Non compliance with this information can result in death or seri ous personal injuries invalidity WARNING Indicates a possible dangerous situation Non compliance with this information can result in death or seri ous personal injuries invalidity CAUTION Indicates a possibly dangerous situation Non compliance with this information can result in damage to property o...

Page 6: ...serious injury or damage Isolate from mains before installation or dismantling work as well as for fuse changes or post installation modifications Observe the prescribed accident prevention and safety rules for the specific application Before putting into operation check if the rated voltage for the unit conforms with the local supply voltage Emergency stop devices must be provided for all applica...

Page 7: ...ion the device provides a constant conveying capacity for mains voltage fluc tuations through an internal offset The device is controlled via an enable input in such a way that the upstream capacitors are neither charged nor discharged Start Stop NOTE Repair work must be carried out by qualified personnel only We recommend that repairs are carried out on our premises NOTE During switch on internal...

Page 8: ...s PSG1 Supply voltage VAC 230 V 10 Supply frequency Hz 50 60 Output voltage VAC 30 150 Output current mA pp 100 Output frequency Hz 5 300 Preset 75 300 Enable input Contacts or 24 V DC Operating temperature C 0 45 Storage temperature C 10 80 Recommended fuse 10 A Type D MCB Protection class IP 54 ...

Page 9: ...rizontal position 4 2 Installation NOTE Do supply voltage operating voltage of the conveyor and control ler input voltage match Is the controller adequately rated for the rated power of the feed er What is the vibrating frequency of the feeder Connect the unit in accordance with the wiring instructions and ensure that earthing is correct 4 3 Connection possibilities Figure 2 Connections external ...

Page 10: ...Release 1 1 2011 08 06 Page 9 Figure 3 Connections internal Ordering codes for plug Output plug Binder 99 4805 00 03 ...

Page 11: ...electing the menu code using the cursor keys Settings Pressing the cursor key for a short time causes one digit increase decrease holding down for a longer time gives changes in ten digit steps Changed settings are saved when exiting the menu or automatically if a key is not pressed for 60 seconds NOTE New units are factory set see Table 2 Settings For units with unknown settings first recall the ...

Page 12: ...ings for a system can be saved by selecting PUSH in menu C 000 recall settings via menu C 000 US PA NOTE Error messages must be cleared in menu no C 009 by means of Cl err Frequently appearing errors which are not described in this chap ter should be reported to the manufacturer ...

Page 13: ...Release 1 1 2011 08 06 Page 12 ...

Page 14: ...Release 1 1 2011 08 06 Page 13 ...

Page 15: ...Release 1 1 2011 08 06 Page 14 ...

Page 16: ...eck the mains voltage check the fuses and replace if necessary Check the control signals and reset to factory settings if necessary see chapter 5 2 Set tings Conveyor not working Check the mains frequency 50 60 Hz Check whether the oscillation frequency was correctly adjusted reset to factory settings if necessary see chapter 5 2 Settings ...

Page 17: ...229 Leonberg Tel 49 0 71 52 60 08 0 Fax 49 0 71 52 60 08 10 sales afag com www afag com Switzerland Afag Automation AG Zuführtechnik Fiechtenstrasse32 CH 4950 Huttwil Tel 41 0 62 959 86 86 Fax 41 0 62 959 87 87 8 Disposal PSG s that are no longer in use should not be disposed of as complete units but dis mantled into separate materials and recycled Non recyclable components must be disposed of cor...

Reviews: