6.2.4 Assembling, monitoring, replacement of the sensors
On both sides of the module there are two C-slots for the magnetic field sensors
(accessories see
chapter 5.3). The end positions are scanned with two
magnetic field sensors.
Fig. 16
Illustration of magnetic field sensors
1. C-slot
2. Sensor and slot nut
3. Fixing screw
Installation of the sensors
Proceed as follows to install the sensors:
1. Insert the sensor (Fig. 16, 2) with the mounted slot nut into the C-slot.
2. Connect the sensor to the control system.
3. Carry out a function check on the rotary module and check whether the
sensor switches correctly.
4. Adjust the position of the rotary module.
5. Set the sensor to the desired position.
6. Securely fasten the sensor with the fastening screw (Fig. 16, 3).
The sensor is mounted.
Monitoring of the sensors
The end position monitoring of the rotary modules is carried out by clampable
magnetic field sensors. These accessories are listed in
chapter 5.3.
A LED on the sensor is used for function monitoring during end position
monitoring.
If the LED does not change its switching state during end position monitoring,
the sensor is defective and must be replaced!
NOTICE
Make sure that only the prescribed magnetic field sensors are used!