Page 82
22.10.2019
R01.43
4.9.1 Test electrical Connection
This function allows you to check the wiring of driver modules to the aflex to the set
mapping. The test automatically controls each actuator one at a time. The correspond-
ing control signal is checked via the integrated back light board in aflex. If wires are
interchanged or open, this is detected.
Error Outputs of the test:
Status
Description
Red Cross & Channel Name
Actual target do not match, check wiring.
Not Tested
No test has been carried out since the Software start
CH (+) wire connection fault
The control signal does not come in the aflex. The
c wire is open
Interchanged or CH(-) fault
The wires of the channel are interchanged or the
channel wire is open
clientNode connection fault
An aflex Linked ClientNode is offline or not availa-
ble.
General Release is missing
General release must be set to perform the test
Fault ClientNode mapping
No driver ClientNodes have been added to the aflex
software module. ClientNode and Channel Map-
ping.
Not Assigned
The aflex channel has not yet been linked to a driver
channel. Carry out channel mapping