8 Fault elimination
8.1 General notes
This chapter contains general information and safety instructions for
troubleshooting on the compact slide.
8.2 Safety instructions for troubleshooting
Also observe the safety instructions in
Chapter 2 „Safety instructions“ in
this manual.
8.3 Table fault causes and remedy
The following table contains an overview of possible fault causes and how to
proceed to eliminate them. Defective components must be replaced exclusively
by Afag original spare parts.
Fault
Possible cause
Remedy:
The compact slide strikes
firmly in the end positions
Stop/shock absorber not set
correctly
Readjust stop/shock absorber
Firmly strike again in the end
positions
Damping elements defective
Replace damping elements
(
Chapter 5.3 „Accessories")
The compact slide stops in an
end position
No signal on the proximity switch
/ sensor
Readjust proximity switch / sensor
The CS module stops again in
the end position
Sensor defective
Replace sensor (
Chapter 5.3
„Accessories")
WARNING
Danger of injury due to improper work!
Poorly performed troubleshooting work can lead to serious injuries and
damage to property.
The due diligence obligations of the user include ensuring that the
personnel working on eliminating faults appropriately trained and qualified.
Summary of Contents for 50386049
Page 45: ...Assembly instructions EN CS 6 20 CS 6 40 Date 01 06 2021 Version 2 0 45 48 ...
Page 46: ...46 48 Assembly instructions EN CS 6 20 CS 6 40 Date 01 06 2021 Version 2 0 ...
Page 47: ...Assembly instructions EN CS 6 20 CS 6 40 Date 01 06 2021 Version 2 0 47 48 ...
Page 48: ...48 48 Assembly instructions EN CS 6 20 CS 6 40 Date 01 06 2021 Version 2 0 ...