Remaining Parameters
All other parameters are available to be programmed in the same way:
-
Approaching the parameter point
-
Activate programming mode CODE
-
Change the value
-
Save
6
Maintenance Instructions
Replace the fuse
Procedure:
1.
Always disconnect the mains plug before opening the control unit.
2.
Loosen the cover screw.
3.
Replace defective fuse.
4.
Close the housing again.
Troubleshooting
Tabelle 17:
Troubleshooting
Disorder:
Repairing:
Device is not working
Check the mains voltage, if necessary, check
or replace fuses.
Check the control signals
Conveyor has no performance
Chekc if the correct resonant frequency iss et,
if neccessary, change the settings.
Conveyor vibrates too much, mag-
net knocking (noises)
Incorrect setting of the oscillation frequency or
amplitude. CAUTION! Magnet can be de-
stroyed by overheating or mechanical damage
to the magnets by hitting operating.
Setting of the setpoint is too high.
Magnet is hot
Incorrect oscillation frequency set, change if
necessary.
Control input is not working
Control voltage with reversed polarity, check.