Options for Instrument Settings
Table 16:
Options for Instrument Settings
Parameter
Area / Values
Factory Setting
Feeder
Oscillation amplitude
(Feeder capability)
(A)
10
– 99%
10%
Swingfrequency
(F)
20.0
– 99.9 Hz
50.0 Hz
Acceleration ramp soft start
(SA)
0.1
– 2.9 Sek.
2.9 Sek.
Acceleration ramp soft stop
(SS)
0.1
– 2.9 Sek.
2.9 Sek.
Shift on extern given value
(AE)
U / I / P / F
F
Given Value 4
– 20 mA DC
I
Given Value 0
– 10 V DC
U
Given Value Potentiometer 10K
P
Full
– Half shaft driven
(F0)
G / H
G
Control
(d)
0 / 1 / E
E
Sensor
Input inverted
(F1)
O / S
O
Status Vibratory Feeder
Input inverted
(F1)
O / S
O
Duplicate timing relay
(S1/S2)
0.0
– 9.9 Sek.
0.1 Sek. / 0.1 Sek.
Logic Vibration Conveyor
Logic
(L)
U / O / S
O
Inputs
(E6)
0 / 1
1
Inputs
(Eb)
0 / 1
0
Amplitude setting
Origin Display
Push the button.
Point in the second LED appears.
Programming mode active. The amplitude can
be changed.
Use the value keys to set the value.
For example at 75.
Push the button.
It appears briefly that the changes were stored.