Parameter Level b (rolling progression of the parameters)
Table 8:
Parameter Level b
Parameter
Display
Meaning
F1
Parameter F1 defines a logical element
having a valence of S or O. The present
at the input logic signal (logic LO when
the swing drive is running, logical HI
when the vibratory drive is) is processed
according to the set value as follows (that
signal is inverted or not inverted):
O set:
-
Logical HI stays HI
(not inverted).
-
Logical LO stays LO
(not inverted).
S set:
-
Logical HI will be LO
(inverted).
-
Logical LO will be HI
(inverted).
S1
Parameter S1 has the value 0.0 to 9.9
seconds with an increment of 0.1 sec-
onds, and defines the delay of the asso-
ciated input set as follows:
Alternating logic level of LO to HI by F1
not inverted passes after a set time the
logic level HI of logic control, if the logic
level does not change again at the en-
trance. For each logic change times to be
restarted. Alternating logic level of LO to
HI inverted by F1 passes after a set time
the logic level at LO logic control, if the
logic level does not change again at the
entrance. For each logic change times to
be restarted.
-
Drop delay is programmed as if F1
is set O
-
Tightening delay is programmed
as if F1 is set S
S2
Parameter S2 has the value 0.0 to 9.9
seconds with an increment of 0.1 sec-
onds, and defines the delay of the asso-
ciated input set as follows:
Alternating logic level from HI to LO by F1
not inverted passes after a set time the
logic level at LO logic control, unless the
local level does not change again at the
entrance. For each logic change times
are restarted.
Alternating logic level from HI to LO by F1