- 1 -
I
Full Inverter Swimming Pool Heat Pump
iX30T iX35
Thank you very much for purchasing our product, please keep and read this manual carefully beforeyou install the heat pump.
Installation
&
Operation
Manual
PROTEAM ix
Page 1: ...Inverter Swimming Pool Heat Pump iX30T iX35 Thank you very much for purchasing our product please keep and read this manual carefully before you install the heat pump Installation Operation Manual PR...
Page 2: ...ist No Name Qty Remark 1 Installation Operation Manual 1 2 Wire controller 1 3 Wire controller box and sponge pad to be installed on the heat pump shell 1 4 Drain pipe 2 m 1 5 Drain pipe connector 1 6...
Page 3: ...mp will not be used all water must be drained from the unit during winter or it could freeze inside the unit causing damage to the internal components Content Accessories 4 Safety 5 Heat pump working...
Page 4: ...the water pipes valves filter equipment sterilizing equipment used for the swimming pool heating circulation pipe system will depend on the project design We do not recommend to install auxiliary ele...
Page 5: ...emperature 8 C Max outlet Water Temperature 40 C If the system is planned to be used with water temperatures that are outside this range please contact Proteam The installation should be done by quali...
Page 6: ...e work is carried out by qualified technicians Incorrect installation may result in damage to the heat pump electric shock fire injury leakage etc Please ensure that any repairs are carried out by qua...
Page 7: ...outside air and directs it over the surface of the EVAPORATOR energy collector The liquid refrigerant inside the EVAPORATOR coil absorbs the heat from the outside air and becomes a gas The warm gas in...
Page 8: ...l can be maintained between 26 C and 32 C 3 2 Air source heat pump working principle 4 way valve Water inlet Water Outlet Condenser Gas liquid separator Compressor Filter Expansion valve Filter Ev apo...
Page 9: ...installation and maintenance servicing Install in a dry well ventilated place and make sure there are no obstructions around the air inlet and outlet Make sure the supporting base is strong enough and...
Page 10: ...igure 2 Horizontal installation space requirements mm 4 4 Heat pump dimensions Figure 3 Heat pump dimensions iX 30 ix 30T iX 35 A B C D E F G H I J K iX 30T iX 35 738 1084 445 401 187 710 187 102 440...
Page 11: ...eft panel 19 Right panel 6 Left frame support 20 Controller 7 Evaporator 21 Electrical terminal cover 8 Fan motor mounting bracket 22 Electrical terminal block 9 Upper frame 23 Electrical cable suppor...
Page 12: ...ting belts to move carry the units see Figure 5 Use protective plates on the surface of the units when handling to avoid scratches and deformation Double check that the support base is strong enough b...
Page 13: ...ation layer Make sure that there is a stable water flow to prevent excessive throttling Do not handle move or lift the unit by holding the water inlet and outlet pipes use only the holes on the base s...
Page 14: ...nd valves should be insulated 5 2 3 Connection sizes Model No Inlet Outlet ix 30T iX 35 DN50 DN50 The pipe pressure and flow rate should be calculated before selecting the diameter of the pipe pressur...
Page 15: ...s a terminal connection for the pump single phase NOTE For single phase pumps please check the wiring diagram Head of circulation pump height difference between water level and main unit total pipelin...
Page 16: ...oltage Unit power supply circuit must have an effective external grounding Wiring and electrical connections must be made by qualified professionals in accordance with the wiring diagram Power line an...
Page 17: ...installation The heat pump only provides a signal for the circulation pump A separate A C Contactor is required to connect the circulation pump Figure 10 NOTE If pump power is less than 250w connect t...
Page 18: ...ROUND AMBT AMBIENT TEMPERATURE SENSOR WFS WATER FLOW SWITCH LOW LOW PRESSURE SWITCH HIGH HIGH PRESSURE SWITCH COIL EVAPORATOR COIL TEMPERATURE SENSOR OWT INWT INLET OUTLET WATER TEMPERATURE SENSOR NOT...
Page 19: ...19 Figure 12 Electrical wiring diagram...
Page 20: ...er Buttons and Icons 8 2 Start up Locking Attention Before you start the machine please make sure the filtration pump is running and there is water flowing through the heat pump Hold the button for 3...
Page 21: ...s locked the icon appears 8 3 Mode Selected Hold the button for 3 seconds to change the below three operating functions each time Heating function Cooling function Auto function Under Auto function if...
Page 22: ...operates silently Powerful mode Choose this mode that the heat pump operates powerfully 8 4 Set the required temp On the main interface press or to adjust the required water temp Of your pool then pre...
Page 23: ...of Hour and Minute like Clock setting Pay attention There are 3 groups Timer for your every day setting See above photo the icon ON will flash when setting the Timer ON The icon OFF will flash when se...
Page 24: ...ld and for 5 seconds and when the Piping temp is below than Exit defrosting temp the system can enter into Manual defrosting 8 9 Parameters Setting On the main interface hold for 3 seconds to enter Pa...
Page 25: ...d water temp in Auto mode 8 40 27 P04 Adjustment of water temp difference before restart 1 18 1 P05 Stop once the temperature is reached 0 Non stop 1 Stop 1 8 10 Running Parameter checking On the main...
Page 26: ...water temp A03 Ambient temp A04 Exhaust temp A05 Gas return temp A06 Outer piping temp A07 Inner piping temp A08 EEV aperture A09 Compressor current A A10 Radiator temp A11 Voltage value V A12 Freque...
Page 27: ...27 9 Wireless remote control 1 Download the Tuya Smart App Scan the QR code below to download the mobile APP Or search Tuya Smart in App Store IOS or Google play Android 2 Sign up for the first time...
Page 28: ...28 3 Press to add a device 4 Choose Others and Other Wifi on the interface...
Page 29: ...which must be under the same WiFi area 6 Make sure the device controller display is reset Hold and for 3 seconds to make the reset then using your App to enter the WIFI account and password to connect...
Page 30: ...30 7 Press Confirm to start the connection after completing The device is successfully added if it s connect then press Finish...
Page 31: ...31 8 Functions Remark The heat pump APP function includes Turn On Off the machine Temperature setting and display Mode Selection Failure status display...
Page 32: ...connection had been made correctly Check that supply voltage can meet the requirement of rated voltage Check that air inlet and outlet are working correctly Check that the electrical leakage protector...
Page 33: ...ay using a 0 6Mpa air compressor brushed by fine copper wire or flushed with a high pressurized water hose usually once a month If there is too much dirt we can use a paintbrush dipped in gasoline to...
Page 34: ...wer immediately and put the fire out with a fire extinguisher The unit s operating environment should be free of gasoline ethyl alcohol and other flammable materials to avoid explosions or fire Malfun...
Page 35: ...nt water flow Check the water circuit system the opening of by pass kits the running of water pump Ambient Water temp is too high Fan motor speed is abnormal or fan motor has damaged Check the fan mot...
Page 36: ...system jammed Check the piping system Exhause piping temp sensor Purple connector detective Change a new sensor E15 Inlet water temp sensor failure Sensor disconnected or defective Reconnect or repla...
Page 37: ...o high under cooling mode Check the scope of using Refrigerant system is abnormal Check the piping system E42 Inner piping temp sensor failure Sensor disconnected or defective Reconnect or replace sen...
Page 38: ...ressor Mitsubishi Mitsubishi Refrigerant R32 R32 Heat Exchanger Titanium Titanium Air Flow Direction Horizontal Horizontal Water Flow Volume m3 h 10 12 Defrost function 4 way valve 4 way valve Working...
Page 39: ...ally please turn off the unit and cut off the power supply at once then contact our service center or technical department Automated Environmental Systems Ltd Unit 1 1 Wimbledon Avenue Brandon Suffolk...