1) Before you install this equipment, please read this full manual.

2) Ensure that there is good network reception at the location where it 
will be installed.

Installation

Wiring

5) Install the antenna as high as 
possible on the top of the pillar to 
ensure line of sight in all directions for 
best possible reception.

Keep antenna high as possible, and 
above elect audio equipment 
to eliminate interference

Side View

3) Remove the top two security 
screws as shown. Do NOT remove 
the bottom screws.

8) Ensure the 

power is OFF

 

before inserting the SIM card.

9)

 Carefully slide the SIM 

holder

 in the OPEN direction, 

insert the SIM, and slide in the 
CLOSED direction to lock it in 
place. 

Do NOT Force or use a 

screwdriver!

11) Allow 20-30 seconds for the unit to boot up and detect the network. 
Once successful connection has been made, the unit will sound a 
confirmation tone and the GSM LED will begin flashing.

Programming Quick Start Guide

Programming is carried out by sending SMS texts to the unit.

3) 

It is recommended to change the “no answer” time if there is more than 1 

number stored. This stops the unit ringing a number after a set time, and can 
be used to prevent voicemail answering the call. Send the following SMS..

The unit can allow up to 100 telephone numbers to be stored, for users to 
be able to ring the system for automatic entry. This uses caller ID like a 
phone to determine the identity of the caller. First, the unit must know what 
country it is operating in. 
4) Program the country code as follows..

GSM-3AB & ABK
GSM-3HB & HBK
 V3.5 (1200 keypad)

1) First check reception. Send the following SMS to the unit...

2) Program the numbers you wish the unit to dial when the call button is 
pressed, up to a maximum of 3 numbers. Each SMS must start with the pass 
code, default 1234, in the following format *12*1234#, followed immediately 
by a command. E.g to program the telephone number 0987654321, enter 
the following SMS..

*20#

*12*1234#

11

0987654321

#

Pass code

Function code

Data

Up to 3 numbers can be sent together in a single SMS as 
follows..

*12*1234#

11

tel.number1#

12

tel.number2#

13

tel.number3#

11 = Telephone number 1
12 = Telephone number 2
13 = Telephone number 3

*12*1234#

52

??#

Where ?? can be 2 digits from 10-99 seconds, default is 20.

*12*1234#

71

??#

Up to 3 numbers can be sent together in the same SMS. Just 
add 72 then the number, then # each time. The pass code only 
needs to be put at the beginning of each new messge.

5) Enter the telephone numbers required to have access control. Do not enter 
country code, just the complete number as you would dial it..

*12*1234#

72

0987654321#

Where ?? can be 1-3 digits. For uk, insert 44, for Ireland 353, for 
USA insert 1. Do not use any leading zeros.

Additional Programming Parameters

Remember to begin each new SMS with pass code *12*1234#

Entrance 

Pillar

Speech 

Unit

4-5 feet 

minimum

200mm 

min

The front door will hinge downwards 
to allow access for mounting holes 
and connection terminals.

Note: The protective film on the front 
of the intercom should not be removed 
until fully installed.

AC

AC

VCC

N

/C

COM

N/O

GND

PB

GND

DETECT

+

GSM 

modem

Output

Optional 

input limit 

switch 

from gate

Exit button

Call Button

Optional keypad 

module

Hinge front door

Side View

4) Use appropriate wall fixings. 8-
10mm anchors, 75mm deep with M5 
screw are recommended as a 
minimum.

Antenna connector. 

Finger tighten only!

SIM card 
holder

Power LED

GSM LED

CPU LED

6) Carefully follow the 
wiring instructions. 
Additional wiring 
suggestions for electric 
strike lock and magnetic 
lock are shown overleaf.

7) Register your SIM card 
with the network, and check 
it works in a mobile phone 
first. If you are using a Pre-
pay or Pay&Go SIM, it will 
need topped up first. Your 
SIM should be GSM 
compatible.

SIM card

If there is a fault or problem, the unit will emit a series of bleeps or warning 
tones. If this occurs, check...
1) That the SIM card has been activated and has credit.
2) That the SIM card does not require a PIN code, disable this in a phone.
3) That the SIM card can make and received a call on a phone.
4) If the SIM card was purchased with a phone, that it is not locked to that 
phone. Call the network operator to check.
5) Switch off power, remove and reseat the SIM card and try again.

10) After a final check of 
wiring, switch on the power. 

open

close

01

????

#  

Change programming password. 

1234

Code

Description

Default

Change access control password (allows users not in caller ID list 
to call intercom and use pass code to activate relay). 

5678

Change monitoring mode password (dial to listen in mode) 

1212

Delete a button calling number, where 

n

 = number 1,2 or 3.

N/A

Speaker volume. Where 

?

 = level 0 - 3

Microphone volume. Where 

= level 0 - 3

3

3

02

????

#  

03

????

#  

1n*#

3

?

#

4

?

#

51

?

#

Relay time. Where 

= 1-9999 seconds.

1 sec

53

??

#

Max call time. Where 

???

 = 005-999 seconds (3 digit code)

60 sec

55

??

#

Max monitoring time (for listen in mode when calling the intercom)

00-60 mins. 00 = no limit.

10 min

57

??

#

Unit can call or SMS service number by set duration to prevent 
SIM card deactivation if seldom used. 

00-60 days. 00 = no inform.

00

65

?

#

Dial in mode for withheld numbers or non stored numbers. 1 = 
answer the call & wait for pass code. 2 = answer the call & 
automatically activate 2 way speech.

1

73

??

#

Delete phone number for caller ID access.

73*#

Delete all phone numbers for caller ID access.

N/A

N/A

77

number

#

Store service number to receive scheduled SMS or call from 
intercom.

N/A

77*#

Delete service number.

999#

Restore defaults

N/A

N/A

-

12v dc

Check stored numbers. Note: no pass code needed for this 
command. O = dial out number. I = Dial in number.

*21#

N/A

58

?

#

Choose between scheduled call to service number or send SMS to 
service number. ?=1 for SMS, 2 for call.

1

Searching

Network found

Standby

Busy

1-12

Poor

13-20

Medium

21-31

Good

The unit should reply SIGNAL LEVEL = ?
Where ? will be between 1 and 31
Below 14 can cause problems with relay 
operation, or no voice from the gate to the 
house. Take action to improve reception.

+

Keypad Connections 

(only keypad models)

-

12-24v

dc

N/C

COM N/O

N/C

COM

N/O

egress

OUT1 OUT2

OUT3

N/C

COM

N/O

K or A

DU out

(-)GND

Sense

INT Lock

Tamper

N/C

USA customers 

– For some networks, you may need to enter the numbers with the long distance 1 

before area code, then the number. E.g. 1-702-555-1234. Try it with and without to see method works.

ARCHITECTURAL 

MODEL

HOODED

 MODEL

O/P1 inhib

Note: PSU 
should be 
located 
within 2 
meters (6 
feet)

LocksOnline Ltd

Tel  +44 (0) 845 230 02 01   |    Email  [email protected]

www.locksonline.co.uk

Reviews: