20
PARAMETER CHECKING AND ADUSTMENT
Parameter list
Some parameters can be checked and adjusted by the controller. Below is the parameter list.
No.
Name
Instruction
1
Compressor running Frequency
Current hz
2
EEV Open degree
Current Value/5
3
Ambient Temperature
Current
℃
4
Outlet Water Temp.
Current
℃
5
Exhaust gas Temp.
Current
℃
6
Return gas Temp.
Current
℃
7
Coil Temp.
Current
℃
8
4-way Valve outlet Temp.
Current
℃
9
Water Circulaton Pump
0-off
;
1-on
10
4-way Valve Status
0-off
;
1-on
11
Standby
/
12
Standby
/
13
Standby
/
14
Standby
/
15
Standby
/
16
Running Current of Compressor
Current*10
17
Voltage
Current/10
18
Standby
/
19
Standby
/
20
Standby
/
21
Fan speed
Current/10
Malfunctioning of the unit and maintenance
When an error occurs or the protection mode is set automatically, the circuit board and the wired
controller will both display the error message.
Error
Meaning
Analysis
Diagnosis
Solution
P01
Water Flow failure
1.
No water flow;
1.Check if water in valve is closed or no
water in;
1.
Open the valve;
2.
Change a new flow switch;
Summary of Contents for EFI 14
Page 1: ...0 Eco Full Inverter Swimming Pool Heat Pump...
Page 2: ...1 EFI Series Heat Pumps...
Page 3: ...0...
Page 5: ...1 Please read carefully...
Page 15: ...9 13 Reactance 26 Balance tank...
Page 17: ...11...
Page 34: ...28 WIRING DIAGRAM Please refertothe wiringdiagram on the electricbox Model EFI14 17 21...
Page 37: ...31...
Page 38: ...32 User Manual for APP Application EFI Full Inverter Series...
Page 39: ...33 CONTENT Download the APP 34 Register 36 Configuration of APP 37 Operation of APP 41...
Page 41: ...35...
Page 48: ...42 11 Add heat pump unit button 12 Refresh button...