AES calpeda META Quick Start Manual Download Page 1

Variable speed pressure boosting system with integrated control

Page 

11 

English

Page 

13 

English

MÈTA

QUICK START

 

OPERATING INSTRUCTIONS

 

Reg. U.S. Pat. and TM. Off.

META_S_Rev7-s13.indd   1

META_S_Rev7-s13.indd   1

03/02/23   09:47

03/02/23   09:47

Unit B, Anglian Lane,

Bury St. Edmunds, Suffolk, IP32 6SR

01842 819130

  

[email protected]

www.automatedenvironmentalsystems.co.uk

Summary of Contents for calpeda META

Page 1: ...glish MÈTA QUICK START OPERATING INSTRUCTIONS Reg U S Pat and TM Off META_S_Rev7 s13 indd 1 META_S_Rev7 s13 indd 1 03 02 23 09 47 03 02 23 09 47 Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk www automatedenvironmentalsystems co uk ...

Page 2: ...p has an intermittent operation discontinuous flow decrease the parameter AP06 by 0 1bar steps as long as the operation is continuous 2 2 Close the tap at of the flow rate 2 litres per minute in these conditions the pump must work intermittently opened tap 2 l min Intermittent operation If the pump has a continuous operation continuous flow increase the parameter AP06 by 0 1bar steps as long as th...

Page 3: ...information and warnings that must be observed otherwise the machine could be damaged or personnel safety could be compromised i Notes and warnings for the correct management of the machine and its parts Operations that can be performed by the final user After carefully reading the instructions they are responsible for maintenance under normal conditions They are authorised to perform routine main...

Page 4: ... swimming pools when there are people in the water 2 3 Marking The following picture is a copy of the name plate that is on the external case of the pump 1 Pump type 2 Flow rate 3 Head 4 Maximum absorbed power 5 Supply voltage 6 Rated current 7 Notes 8 Frequency 9 Operation Duty 10 Insulation class 11 Weight 12 cosø 13 Rated speed 14 Protection 15 AAAA Year of manufacture 15 XXXX Serial number 16 ...

Page 5: ...ackaged device The transport vehicles must comply for the weight and dimensions with the chosen product see overall dimensions in technical catalogue 5 1 Handling Handle with care the packages must not be subject to shocks Avoid placing other material on the packages that could damage the pump If the weight exceeds 25 kg the package must be handled by two people at the same time 6 INSTALLATION 6 1...

Page 6: ...ameters Alarms 7 2 Pump status parameters They allow you to view Initial screen rUn OFF StB Err Motor operating frequency Delivery pressure measured by the transducer Supply current input Supply electrical power input Supply voltage Starting from the main screen press the arrows plus or minus to view the other parameters 7 3 Programming parameters To view the programming parameters select menu The...

Page 7: ...al users AP03 is disabled by default but values from 0 to 240 minutes can be entered 7 5 5 Enabling safe start The safe start function can be enabled This function prevents pressure peaks in the pipework The Safe start function is triggered whenever the power supply is cut off To enable this function it is necessary to set the parameter AP04 with a value other than zero default At every interrupti...

Page 8: ...eter UP01 UP02 the membrane pre charge pressure must be changed to 0 5 bar lower than the re start pressure i e 2 9 bar re start pressure membrane at 2 4 bar par 14 chap 6 ATTENTION Do not pre inflate the tank membrane over 3 5 bar if a higher pressure is required install an external tank If the pump works for long periods of time with a flow rate of 2 litres min or lower it is necessary to instal...

Page 9: ...y where the device is dismantled as well as the international laws for the protection of the environment 11 SPARE PARTS 11 1 How to order spare parts When ordering spare parts please quote their designation position number in the cross section drawing and rated data from the pump name plate type date and serial number The spare parts request can be sent to CALPEDA S p A by phone or email 11 2 DESI...

Page 10: ...omatically and makes one attempt every 10 minutes for a total of 5 attempts Er08 Blockage due to internal overheating AUT Overtemperature detected on the board The error is restored when the temperature drops Er09 Blockage due to overpressure MAN Pressure higher than 8 3 bar Er10 Thermal protector intervention detected MAN Motor overheating Er11 Blockage due to presence of air MAN Presence of air ...

Page 11: ...ank of maximum 8 litres 5 intermittent operation 5 Resonances between pump and hydraulic system control dynamics 5 Set AP05 1 6 Insufficient flow 6a Pipes and accessories with diameter too small causing excessive loss of head 6b Presence of deposits or solid bodies in the internal passages of the impeller 6c Impeller deteriorated 6d Worn impeller and pump casing 6e Excessive viscosity of the liqui...

Page 12: ...ung Remplissage Llenado Fyllning Vullen Γέμισμα ç ÔÓÎÌÂÌË 灌泵 Fig 5 Scarico Draining Entleerung Vidange Vaciado Avtappning Aftappen Αποστράγγιση ëÎË 排空 Fig 2 Funzionamento in aspirazione Suction lift operation Saugbetrieb Fonctionnement en aspiration Funcionamiento en aspiración Sugande funktion Zuigsituatie Θέση λειτουργίας με κάθετη αναρρόφηση ê ÓÚ Â Û Ó Ìfl ÊË ÍÓÒÚË 负吸水头工作 Fig 3 Sostegni ed anco...

Page 13: ...stalaciones Installationsexempel Installatievoorbeelden Παραδείγματα εγκαταστάσεων è ËÏÂ ÛÒÚ ÌÓ ÍË 安装示意图 Fig 6 Pressione serbatoio Vessel pressure Behälter Vordruck Pression du réservoir Presión del acumulador Hydrotubens tryck Давление в баке 容器压力 META_S_Rev7 s13 indd 76 META_S_Rev7 s13 indd 76 03 02 23 09 47 03 02 23 09 47 ...

Page 14: ...4 12 14 16 14 24 14 00 14 64 14 66 16 17 16 14 16 15 16 16 28 08 28 04 25 01 22 16 16 00 16 02 82 02 25 05 25 07 14 04 14 06 17 20 17 00 17 04 17 06 17 08 17 10 36 52 25 02 28 00 64 13 64 13 28 00 64 13 64 13 36 54 36 00 14 20 34 00 46 00 82 00 82 08 76 00 82 04 81 00 78 00 36 51 73 00 76 16 98 04 98 51 98 00 98 70 98 08 96 02 98 20 98 55 98 54 98 56 98 57 98 58 98 71 98 72 98 64 98 75 98 52 98 74...

Page 15: ... Ò Ó ÍË 组装与分解图 22 12 14 12 14 16 14 24 14 00 14 64 16 17 16 17 22 16 16 00 16 16 16 15 16 14 14 04 14 06 14 47 25 05 17 20 17 00 17 04 17 06 17 08 17 10 36 54 36 00 14 20 34 00 46 00 70 00 28 00 36 52 25 02 28 00 64 15 64 13 82 00 92 00 88 00 90 00 90 04 76 00 82 04 81 00 78 00 36 51 73 00 28 08 28 04 25 01 76 16 98 04 98 51 76 06 98 00 98 70 98 63 98 60 98 08 96 02 98 54 98 20 98 55 98 56 98 52 9...

Page 16: ... 36050 Montorso Vicentino VI Italy We Calpeda S P A declare that the undersigned company certifies under its sole responsibility that the pumps specified below satisfy the following requirements of UK regulations Pump Models MÈTA MÈTA SMALL UK Regulations Supply of Machinery Safety Regulations 2008 Electrical Equipment Safety Regulations 2016 Electromagnetic Compatibility Regulations 2016 The Rest...

Page 17: ...L pomptype en serienummer zoals vermeld op de typeplaat aan de EG voorschriften 2006 42 EU 2011 65 EU 2014 30 EU 2014 35 EU voldoen SF VAKUUTUS Me CALPEDA S p A vakuutamme että pumppumme MÈTA MÈTA SMALL malli ja valmistusnumero tyyppikilvcstä ovat valmistettu 2006 42 EU 2011 65 EU 2014 30 EU 2014 35 EU direktiivien mukaisesti ja CALPEDA ottaa täyden vastuun siitä että tuotteet vastaavat näitä stan...

Reviews: