Out of the Box
1. IntelliPro Module (1)
AES Part# 72-7094A
2. RJ11 Cable (1)
AES Part# 13-0395
3. Kepnuts (4)
AES Part# 09-1006
4. Insulating washer (2)
AES Part# 09-7X94
Overview
The 7094A full data module is an alarm reporting interface for the AES
Model 7007 Security Subscriber Unit. The 7094A is UL listed for use in
Commercial Security Installations with or without a phone line. This
document describes installation of AES Model 7007 subscriber with the
interface to an Alarm Panel (AP) via the AP dialer interface. The 7094A
decodes a CID, PULSE, Modem II, or a Modem III message received on its
AP phone interface and sends the message via the AES subscriber radio.
The 7094A also provides a full replacement to a POTS line as well as POTS
monitoring when POTS is present.
User Interface
A web browser and network connection to the Model 7007 subscriber is
required to program the 7094A. The 7094A has one STATUS LED to
indicate operation and heartbeat.
Installation
1.
Be sure primary and battery backup power to the subscriber are
disconnected.
2.
Remove the four (4) lower hex nuts holding the main board inside
the 7007 enclosure. Save the nuts.
3.
Mount the 7094A board on standoffs, and secure with 4 kepnuts
(provided with 7094A).
4.
Install insulating washer (provided with 7094A) over H1 (upper left
corner) H3 (lower left corner).
5.
Secure the 7094A with the 4 nuts removed in Step 1 above.
6.
Install the 6 wire modular cord (provided) between 7094A J1 and
7007 subscriber connector J7 ARM. Power up the subscriber.
LIMITED PRODUCT WARRANTY:
AES warrants to the original purchaser
that the AES Subscriber Unit will be free from defects in material and workmanship
under normal use and service for three (3) years from the date of original
purchaser’s purchase. Except as required by law, this Limited Warranty is only
made to the original purchaser and may not be transferred to any third party. This
Limited Product Warranty is made in lieu of any other warranties, expressed or
implied, it being understood that all other warranties, expressed or implied,
including of merchantability or fitness for a particular purpose, are hereby
expressly excluded. AES assumes no liability for any personal injury, property
damage, consequential damages, or any other loss or damage due, among other
things, to this product’s failure to operate or provide adequate warning. AES’s sole
responsibility is to repair or replace, at AES’s sole option, the AES product that is
judged defected by AES during the limited warranty period under the terms of its
Limited Warranty.
Firmware Version
The firmware version is displayed in the web browser Status page
under the Hardware–Panel Interface.
7094A Configuration
Select the Accessories page. Use controls in the IntelliPro panel to
set parameters.
Item
Parameter
Default value
1
Phone line
No
2
Intercept Number
555
3
AP Report Format
CID
4
AP input gain
20
5
Intercept on blind dial
No
6
Line Cut Report
Yes
7
POTS Cut Report Delay
45 sec
8
POTS Restoral Delay
60 sec
9
AP ACCT Override
No
10
POTS Input Gain
20
11
Advanced Options Display
No
12
AP Output gain
3
13
Reset to defaults
-
14
Line-cut sensing Enabled
Yes
15
CID 4xx Letter
U
16
M3 EC TEXT to CID
Yes
17
Voltage Pump Enabled
Yes
18
Clock Freq. Shift Enabled
No
CONFIGURATION SETTINGS
Phone line: YES or NO for POTS line presence.
Intercept Number: Enter a phone number such as 555.
AP report format: CID, MODEM and PULSE depending on Alarm
Panel.
FOR MODEM SELECTION
AP MODEM format: Set to MODEM2 or MODEM3. If you select
MODEM3 format, set Advanced Options to YES to set M3 Text to CID.
This table shows panel models tested and the MODEM format supported.
Panel Model
Revision Number
Format Tested
D7412GV2
7.08
Modem III
D7412GV3
8.03
Modem III
D8112E1/G1
22
Pulse Only
D8112G2
31.31
Modem II
D6112
4.0
Modem II
D2212B
3.03 (IIe = III)
Modem III
D4412
1.12
Modem III
D9412G
6.6
Modem III
FOR PULSE SELECTION
Parameter
Default value
Available values
Handshake Duration (HSD)
0.8 sec
0.8, 0.4
Handshake Frequency (HSF)
1.4 KHz
1.4, 2.3
Center Frequency (CF)
1.8 KHz
1.8, 1.9
Inter-Digit Time (IDT)
0.7 sec
0.7, 0.9, 1.7
Inter-Round Time (IRT)
3.0 sec
3.0, 5.0
Quick Start Guide
AES Model 7094A IntelliPro
Page 1 of 2
AES Corporation
To view the complete Installation Manual, refer to website:
http://aes-corp.com
40-7094A-QSG Rev. 4 4/15/2019