AES 603AB Installation Manual Download Page 1

Installation Manual

for

603AB, 603ABK, 603HB, 603HBK Wireless Intercom System

MENU

12.21

Charging 

base

Entrance 

Pillar

Transmitter / receiver - Keep 
away from ground, as high as 
possible. For best results, do 
not install too close to sources 
of electrical interference e.g. 
gate automation panel

Speech 

Unit

House or 
reception 

area

Note: Wood and glass only 
reduce signal strength by 
10-20%. Masonry will reduce 
signal strength by 20-50% 
per wall. Metal can totally 
block signals.

For longer range 
applications, locate the 
handset near a window at 
front of property.

150m 

Typical

Installation

1) Before installing fully, test the range of the system. Wire the unit as per 
wiring diagram, place the equipment in the desired location and test 
operation.

2) Ensure that the gate transmitter / receiver unit is installed to facilitate 
line of sight with the property or reception area. To achieve best results, 
mount the unit as high as possible from the ground. Should you need to 
extend range, you can mount it on a small pole to elevate it a few meters 
from the ground.

3) It is recommended to charge the handset for 7-8 hours before use.
4) Power up the handset after inserting the batteries.
5) Wire the door station and transmitter / receiver according to the diagram 
below..

Never drill holes in 

the top of the 

enclosure. Cable 

entry should be 

through the bottom.

Screened CAT 5

8 meters max

602 Range

Intercom

Transmitter

Mount AB model 
to wall with 
10mm x 50mm 
large wall 
anchors to 
prevent removal 
or theft.

-

+

12v

dc in

+

-

N/O

N/C

Shielded CAT5 cable

Solid 

shield 

wire

Volt free

Relay output

(4 sec pulse)

Code 

button

Note: For improved audio 
performance, the shield 
wire can be connected to 
bolts on metal housing of 
speech panel.

Testing

1) Check all connections are correct before switching on the power.
2) Press the call button on the speech panel.
3) The handset should ring.
4) Press the         button to answer the call and check two way speech.
5) Press         to check the door / gate release function works.

Handset & Operation

Power 

LED

ON/OFF

Vibration

ON/OFF

Voicemail

Symbol

Battery 

Level

Reception 

indicator

ADJUST VOLUME
Press     or      to adjust volume level, 
and press MENU to select and save.

CHANGE RING TONE
Press      and the unit will ring under 
the currently select tone. Press      
and        to cycle through available 
ring tones. Press MENU to select 
and save.

CHANGE LANGUAGE
Press      and the unit will display the 
currently selected language. 
1=English. Press      and        to 
cycle. Press MENU to select and 
save.

VOICEMAIL
When the door station is pressed, and not answered within 40 seconds, 
the visitor can leave a message. Once complete, the handset will display 
the        symbol. Up to 16 messages can be saved.

To listen to voicemail, press MENU to play. If there are more than 1 
message, press       and         to select the message required and press 
MENU to play.

= Pause / Exit

= Continue

= Delete, long 
press = delete all.

SET TIME ON DISPLAY
Press MENU for 2 seconds. The hour digits will begin flashing.
Press       or          to adjust. Press MENU to cycle from hour setting to 
minutes and repeat. Press MENU a third time to exit and save changes.

Coding another handset to the System

Code 

Button

Foil screening 

wrapped 

around MIC 

wires for best 
performance!

+

-

GND

MIC 

connections

To add an extra handset to the system, follow the sequence below..
1) Press and HOLD the code button on the door station for 3 seconds, 
until the LED’s on the bottom of the board start to flash.
2) Press and hold the Code button on the new handset ignoring the first 
short tone, until you hear a confirmation tone (

“Di-Do-Do”). This may take 

up to 10 seconds.
3) Once the door station lights stop flashing, then you can test the 
system by pressing the call button on the door station. The new handset 
should ring. If not, repeat the process from the top.

(keep short for better audio)

+ -

12v 

dc

+

Keypad Connections 

(ABK model)

-

12-24v

dc

N

/C

C

O

M

N

/O

N

/C

C

O

M

N

/O

e

g

re

s

s

OUT1 OUT2

Ver 3
1200 keypad model

C

Note: For earlier models, the existing master handset lights will 
flash after step 1. You will need to press the MENU button on the 
existing handset first, before proceeding to step 2 above.

OUT3

N/C

COM

N/O

K or A

DU out

(-)GND

Sense

O/P1 inhib

INT Lock

Tamper

N/C

Note: Keypad volt free output(s) needs connected to gate control panel or electric door 
lock as well as relay output from the intercom controller PCB. Parallel connect C and N/O 
contacts for electric gate controller or strike lock. Series connect C and N/C contacts for 
magnetic lock.

3) Remove the top two security 
screws as shown. Do NOT remove 
the bottom screws.

The front door will hinge downwards 
to allow access for mounting holes 
and connection terminals.

Note: The protective film on the front 
of the intercom should not be removed 
until fully installed.

Call Button

Optional keypad 

module

ARCHITECTURAL 

MODEL

HOODED

 MODEL

Reviews: