-IO Expansion Board
Soloist HPe 50/75/100
Chapter 3: -I/O Expansion Board
The -IO option board is 16 digital opto-inputs, 16 digital opto-outputs, 3 analog inputs, 3 analog outputs, and a
brake/relay output.
D A N G E R : Always disconnect the Mains power connection before opening the Soloist HPe
50/75/100 chassis.
Figure 3-1:
Soloist HPe 50/75/100 with -IO Option Board
Table 3-1:
-IO Expansion Board Jumper Configuration
Jumper
Setting
Description
JP2
1-2
PSO Output Active High, Low Z during reset
2-3
(1)
PSO Output Active Low, High Z during reset
JP3
1-2, 3-4
Switch Brake +
5-6, 7-8
(1)
Switch Brake -
1-3
Relay Only
(1) default
Table 3-2:
-IO Option Board Fuse Information
Fuse
Description
Size
Aerotech P/N
Manufacturer's P/N
F1
+5 VDC User Power
3 A, resettable
EIF01001
Raychem RGE300
www.aerotech.com
Chapter 3