![Aerotech Soloist CP 10 Hardware Manual Download Page 11](http://html1.mh-extra.com/html/aerotech/soloist-cp-10/soloist-cp-10_hardware-manual_2863050011.webp)
Electrical Safety
Soloist CP
Safety Procedures and Warnings
This manual tells you how to carefully and correctly use and operate the Soloist CP. Read all parts of this
manual before you install or operate the Soloist CP or before you do maintenance to your system. To prevent
injury to you and damage to the equipment, obey the precautions in this manual. The precautions that follow
apply when you see a Danger or Warning symbol in this manual. If you do not obey these precautions, injury
to you or damage to the equipment can occur. If you do not understand the information in this manual,
contact Aerotech Global Technical Support.
This product has been designed for light industrial manufacturing or laboratory environments. The protection
provided by the equipment could be impaired if the product is used in a manner not specified by the
manufacturer.
N O T E :
Aerotech continually improves its product offerings; listed options may be superseded at any
time. All drawings and illustrations are for reference only and were complete and accurate as of this
manual’s release. Refer to www.aerotech.com for the most up-to-date information.
D A N G E R : This product contains potentially lethal voltages. To reduce the possibility of
electrical shock, bodily injury, or death the following precautions must be followed.
1. Disconnect electrical power before servicing equipment.
2. Disconnect electrical power before performing any wiring.
3. Access to the Soloist CP and component parts must be restricted while connected to a
power source.
4. To minimize the possibility of electrical shock and bodily injury, extreme care must be
exercised when any electrical circuits are in use. Suitable precautions and protection must
be provided to warn and prevent persons from making contact with live circuits.
5. Install the Soloist CP inside a rack or enclosure.
6. The shunt resistor temperature can exceed 70°C during normal operation and contains
lethal voltage on its terminals and surface. It must be properly enclosed and shielded to
avoid risk of fire and operator shock.
7. Do not connect or disconnect any electrical components or connecting cables while
connected to a power source.
8. All components must be properly grounded in accordance with local electrical safety
requirements.
9. Operator safeguarding requirements must be addressed during final integration of the
product.
D A N G E R : The Soloist CP case temperature may exceed 70°C in some applications.
www.aerotech.com
11
Summary of Contents for Soloist CP 10
Page 1: ...Revision 4 09 00 Soloist CP Hardware Manual...
Page 14: ...Soloist CP Quick Installation Guide 14 www aerotech com This page intentionally left blank...
Page 24: ...Soloist CP Introduction 24 Chapter 1 www aerotech com This page intentionally left blank...
Page 90: ...90 Chapter 3 www aerotech com Figure 3 7 Digital Inputs Soloist CP IO Expansion Board...
Page 100: ...100 Chapter 4 www aerotech com Soloist CP Accessories This page intentionally left blank...
Page 108: ...Soloist CP Revision History 108 Appendix B www aerotech com This page intentionally left blank...