Aerotech MPS50SL Hardware Manual Download Page 38

Maintenance

MPS50SL Hardware Manual

4.2. Cleaning and Lubrication

D A N G E R :  Remove power before connecting or disconnecting electrical components or
cables. Failure to do so may cause electric shock or damage to the equipment.

W A R N I N G :  In applications that have multiple stages bolted together to form multi-axis
systems, the orthogonality may be lost if the stage tables of the support stages are loosened.
Precision aligned stages should not be loosened or disassembled.

W A R N I N G : Further disassembly of the stage is not recommended because proper
assembly and calibration can only be done at the factory. In addition, a laser interferometer is
required for post assembly verification to maintain warranties. Contact Aerotech for more
information.

Cleaning

Before using a cleaning solvent on any part of the MPS50SL, blow away small particles and dust with
nitrogen or, less preferably, clean, dry, compressed air.

Any external metal surface of the MPS50SL can be cleaned with isopropyl alcohol on a lint-free cloth.
Harsher solvents, such as acetone, may damage the plastic and rubber seals on the drive screw or damage
the precision rail guides. If acetone is required, avoid the screw and bearing seals. Acetone can also damage
the black paint on the motor and encoder covers

W A R N I N G :  Make sure that all solvent has completely evaporated before attempting to
move the stage.

38

Chapter 4

www.aerotech.com

Summary of Contents for MPS50SL

Page 1: ...Revision 1 01 00 MPS50SL Hardware Manual...

Page 2: ...ech com Phone 1 412 967 6440 Fax 1 412 967 6870 101 Zeta Drive Pittsburgh PA 15238 2811 www aerotech com United Kingdom China Email Support aerotech com Phone 44 0 1256 855055 Fax 44 0 1256 855649 Ema...

Page 3: ...ns 16 2 3 Securing the Stage to the Mounting Surface 19 2 3 1 For XY Assemblies and Special Cases 21 2 4 Attaching the Payload to the Stage 22 Chapter 3 Electrical Specifications and Installation 25 3...

Page 4: ...es 22 Figure 2 8 Stage Orientations 23 Figure 2 9 Torque Required to Turn Drive Screw in Vertical Orientation 24 Figure 3 1 Motor and Feedback Wiring M1 Option 31 Figure 3 2 Motor and Feedback Wiring...

Page 5: ...edback Connector Pinouts M1 27 Table 3 2 25 Pin D Motor Mating Connector M1 27 Table 3 3 25 Pin D Motor and Feedback Connector Pinouts M1 with HV Option 28 Table 3 4 25 Pin D Motor and Feedback Connec...

Page 6: ...Table of Contents MPS50SL Hardware Manual 6 www aerotech com This page intentionally left blank...

Page 7: ...ent parts must be restricted while connected to a power source 2 Do not connect or disconnect any electrical components or connecting cables while connected to a power source 3 Disconnect electrical p...

Page 8: ...Electrical Safety MPS50SL Hardware Manual 8 www aerotech com This page intentionally left blank...

Page 9: ...re declares that it is not allowed to put the equipment into service until the machinery into which it is to be incorporated or of which it is to be a component has been found and declared to be in co...

Page 10: ...Declaration of Conformity MPS50SL Hardware Manual 10 www aerotech com This page intentionally left blank...

Page 11: ...025 25 mm travel 050 50 mm travel Drive Screw Required BS Precision ground ball screw 1 mm rev LS Precision ground lead screw 0 5 mm rev Vacuum Preparation Optional HV High vacuum preparation to 10 6...

Page 12: ...he system in a low vibration environment Excessive floor or acoustical vibration can affect system performance Contact Aerotech for information regarding your spe cific application Protection Rating T...

Page 13: ...m 1 5 m Straightness 2 0 m 3 0 m Flatness 2 0 m 3 0 m Maximum Speed 1 0 mm rev Ball Screw DC Motor M1 5 mm s 5 mm s Stepper Motor M2 1 mm s 1 mm s 0 5 mm rev Lead Screw DC Motor M1 2 5 mm s 2 5 mm s...

Page 14: ...in a clean environment and use powder free polyethylene gloves to prevent any contaminants from adhering to the surface of the MPS50SL 3 During installation use cleaned vented stainless steel fastene...

Page 15: ...tested at Aerotech Use compressed nitrogen or clean dry oil less air to remove any dust or debris that has collected during shipping Set the MPS50SL on a smooth flat and clean surface Each MPS50SL has...

Page 16: ...tech continually improves its product offerings listed options may be superseded at any time Refer to the most recent edition of the Aerotech Motion Control Product Guide for the most current product...

Page 17: ...MPS50SL Hardware Manual Mechanical Specifications and Installation Figure 2 2 MPS50SL 025 Mounting Plate MP Dimensions Figure 2 3 MPS50SL 050 Mounting Plate MP Dimensions www aerotech com Chapter 2 17...

Page 18: ...Mechanical Specifications and Installation MPS50SL Hardware Manual Figure 2 4 MPS50SL HDZ Angle Bracket Dimensions 18 Chapter 2 www aerotech com...

Page 19: ...face rather than the MPS50SL Shimming should be avoided if possible If shimming is required it should be minimized to retain maximum rigidity of the system Mount the stage to the mounting surface usin...

Page 20: ...Mechanical Specifications and Installation MPS50SL Hardware Manual Figure 2 5 Mounting Hole Locations 20 Chapter 2 www aerotech com...

Page 21: ...onnect all electrical power 3 Mount the stage with M3 low head socket cap screws LHSCS See Table 2 2 for hardware details 4 Reconnect the stage to the power supply and drive the tabletop to the other...

Page 22: ...intain optimum performance N OTE For valid system performance the mounting interface should be flat within 5 m W A R N I N G Refer to the dimensions in Section 2 2 for maximum allowable thread engagem...

Page 23: ...rive screw of an MPS50SL series stage can be found from Figure 2 9 or the following equation Where Lead of Screw see Table 1 3 Efficiency 90 for ball screws 50 for MPS50 lead screws Reduction Ratio 49...

Page 24: ...Mechanical Specifications and Installation MPS50SL Hardware Manual Figure 2 9 Torque Required to Turn Drive Screw in Vertical Orientation 24 Chapter 2 www aerotech com...

Page 25: ...the system separate from this documentation The electrical wiring from the motor and encoder are integrated at the factory Refer to the sections that follow for standard motor wiring and connector pi...

Page 26: ...are any questions on system configuration The System Integrator or qualified installer is responsible for determining and meeting all safety and compliance requirements necessary for the integration...

Page 27: ...hardware limit 8 Reserved 9 Reserved 10 Motor 11 Motor 12 Reserved 13 Reserved 14 Cosine 15 Sine 16 Marker 17 5 V power supply 18 Stage ID 19 Positive CW hardware limit 20 Common ground 21 Common grou...

Page 28: ...CCW hardware limit 8 Common ground 9 Common ground 10 Marker N 11 Sine N 12 Cosine N 13 Reserved 14 Reserved 15 Reserved 16 Motor 17 Motor 18 Reserved 19 Reserved 20 Positive CW hardware limit 21 Rese...

Page 29: ...ed 9 Reserved 10 Motor Return 11 Motor Phase A 12 Motor Phase B 13 Reserved 14 Reserved 15 Reserved 16 Reserved 17 5 V power supply 18 Stage ID 19 Positive CW hardware limit 20 Common ground 21 Common...

Page 30: ...ardware limit 8 Common ground 9 Common ground 10 Reserved 11 Reserved 12 Reserved 13 Reserved 14 Reserved 15 Motor Phase B 16 Motor Phase A 17 Motor Return 18 Reserved 19 Reserved 20 Positive CW hardw...

Page 31: ...al Electrical Specifications and Installation 3 2 Motor and Feedback Wiring Shielded cables are required for the motor and feedback connections Figure 3 1 Motor and Feedback Wiring M1 Option www aerot...

Page 32: ...Electrical Specifications and Installation MPS50SL Hardware Manual Figure 3 2 Motor and Feedback Wiring M2 Option 32 Chapter 3 www aerotech com...

Page 33: ...rent 25 mA Output Type Open Collector Output Voltage 5 V Output Current 10 mA sinking Output Polarity Normally Closed NC l Sinks current to ground Logic 0 when not in limit l High impedance Logic 1 wh...

Page 34: ...tant 0 0036 N m Gear Ratio 676 49 Table 3 9 Stepper Motor Specifications Stepper Motor M2 Stall Torque 0 0036 N m Rated Phase Current 0 15 A Recommended Bus Voltage 24 V Rotor Inertia 4 50E 08 kg m2 F...

Page 35: ...and motor signals and is dictated by the stage wiring refer to Section 3 5 for Motor and Feedback phasing information Programming direction of a stage is set by the controller that is used to move th...

Page 36: ...Electrical Specifications and Installation MPS50SL Hardware Manual 3 5 Motor and Feedback Phasing Figure 3 4 Encoder Phasing Reference Diagram M1 Motor Option 36 Chapter 3 www aerotech com...

Page 37: ...ction interval of once per month is recommended until a trend develops for the application Longer or shorter intervals may be required to maintain the film of lubricant on the bearing surfaces If the...

Page 38: ...he factory In addition a laser interferometer is required for post assembly verification to maintain warranties Contact Aerotech for more information Cleaning Before using a cleaning solvent on any pa...

Page 39: ...upper axis for lubrication and cleaning if possible W A R N I N G Do not attempt to manually back drive a MPS50SL Doing so will damage the MPS50SL 1 Drive the carriage to one end of travel and remove...

Page 40: ...50SL 050 Bearing Cage Creep To correct this problem the cage can be pushed back into position using a bearing centering fixture which is available for purchase from Aerotech Two fixtures are available...

Page 41: ...tage carriage until the fixture bottoms out against the carriage side bearing rail to ensure proper cage centering A tapped hole in the fixture M3 thread is provided to aid in removal of the fixture T...

Page 42: ...ment Manually push the bearing cage toward the stage carriage until the fixture bottoms out against the carriage side bearing rail to ensure proper cage centering Verify cage position against scribe m...

Page 43: ...tion for polarity and compatibility requirements Example voltage requirements Controller trap or fault refer to the Controller documentation Stage moves uncontrollably Encoder sine and cosine signal c...

Page 44: ...Maintenance MPS50SL Hardware Manual 44 Chapter 4 www aerotech com This page intentionally left blank...

Page 45: ...such approval A Return Materials Authorization RMA number must accompany any returned product s The RMA number may be obtained by calling an Aerotech service center or by submitting the appropriate re...

Page 46: ...problem is not warranty related then the terms and conditions stated in the following On Site Non Warranty Repair section apply On site Non Warranty Repair If any Aerotech product cannot be made funct...

Page 47: ...MPS50SL Hardware Manual Revision History Appendix B Revision History Revision General Information 1 01 00 Full revision 1 00 00 New Manual www aerotech com Appendix B 47...

Page 48: ...Revision History MPS50SL Hardware Manual 48 Appendix B www aerotech com This page intentionally left blank...

Page 49: ...pecifications 33 G Global Technical Support 2 grease 14 39 H HDZ Angle Bracket Dimensions 18 Humidity 12 I Inspection Schedule 37 isopropyl alcohol 38 L Limit Switch Specifications 33 lubricants vacuu...

Page 50: ...MPS50SL Hardware Manual T Technical Support 2 Temperature Effects 12 thermal expansion coefficient 12 V Vacuum 14 vacuum guidelines 14 Vibration 12 W Warranty and Field Service 45 50 Index www aerotec...

Reviews: