3.2. Fuse Specifications
WARNING
: Replace fuses only with the same type and value.
Always disconnect the Mains power connection before opening the XR3 chassis. Fuses must not be
changed with Mains power applied to the unit.
The fuses on the drive interface board are factory-configured based on the bus voltage configuration
that you ordered. The fuses are not likely to blow under normal operating conditions.
The most likely reason for a fuse to blow is if you have connected the unit to the wrong AC line voltage.
Table 3-4:
Drive Interface Board Motor Power Fuse Replacement Part Numbers
Bus
Fuse
Description
Aerotech P/N
Manufacturer
P/N
Bus 1
F1 (-VB1 to -VB2)
2 A SLO BLO, 3AG
EIF00102
Littelfuse 313002
F1 (-VB3 to -VB5)
3 A SLO BLO, 3AG
EIF00103
Littelfuse 313003
F1 (-VB7 to -VB8)
Not Used
--
--
F2 (-VB1 to -VB5)
4 A SLO BLO, 3AG
EIF00104
Littelfuse 313004
F2 (-VB7 to -VB8)
7 A SLO BLO, 3AG
EIF00107
Littelfuse 313007
Bus 2
F3 (-VB1 to -VB2)
2 A SLO BLO, 3AG
EIF00102
Littelfuse 313002
F3 (-VB3 to -VB5)
3 A SLO BLO, 3AG
EIF00103
Littelfuse 313003
F3 (-VB7 to -VB8)
Not Used
--
--
F4 (-VB1 to -VB5)
4 A SLO BLO, 3AG
EIF00104
Littelfuse 313004
F4 (-VB7 to -VB8)
7 A SLO BLO, 3AG
EIF00107
Littelfuse 313007
Figure 3-1:
Drive Interface Board
IMPORTANT
: Due to inrush currents, these fuses must be of the Slow Blow type.
XR3 Hardware Manual
3.2. Fuse Specifications
www.aerotech.com
91