![Aerotech Automation1 iXC6e Hardware Manual Download Page 69](http://html1.mh-extra.com/html/aerotech/automation1-ixc6e/automation1-ixc6e_hardware-manual_2863025069.webp)
2.5.5. High-Speed Inputs
High-speed inputs 20 and 21 can be used as general purpose inputs or as the trigger signal for high
speed data collection. Refer to the DriveDataCaptureConfigureTrigger() function topic in the Help file
for more information.
You can use the
external PSO synchronization functions
to synchronize waveform generation with
an external synchronization signal. When you activate this feature, the PSO Waveform module will
not generate the configured waveform when an output event is received until the rising edge of the
synchronization signal occurs.
Table 2-41:
High-Speed Input Specifications
Specification
Value
Input Voltage
5V - 24 V input voltages
Input Current
10 mA
Input Device
HCPL-0630
Delay
50 nsec
Table 2-42:
High-Speed Input Pins on the Auxiliary I/O Connector
Pin#
Description
In/Out/Bi
3
High-Speed Input 20 + / PSO External Sync. +
Input
4
High-Speed Input 20 - / PSO External Sync. -
Input
5
High-Speed Input 21 +
Input
6
High-Speed Input 21 -
Input
Figure 2-35:
High-Speed Inputs
iXC6e/XC6e Hardware Manual
2.5.5. High-Speed Inputs
www.aerotech.com
69