VENTILATION FAN 

MODEL: AP50-S   

WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:   

CAUTION 

1

. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.   

2

. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up for wall 

application.  

3

. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall and construction dust away of motor unit. 

4

. Please read specification label on product for further information and requirements. 

CLEANING & MAINTENANCE 

For quiet and efficient operation, long life, and attractive appearance, lower or remove grille and vacuum interior of unit with the 
dusting brush attachment. 
The motor is permanently lubricated and never needs oiling.     

OPERATION 

Use an on/off switch to operate this fan. See “Connect Wiring” for details.

ASSEMBLY INSTRUCTIONS

MOUNT DIRECTLY TO JOIST OR I-JOIST 

Place the housing assembly in the opening so the bottom edge 
is flush with the finished ceiling. Nail the housing assembly to 
the joist using nails.   

POSITION THE HOUSING ASSEMBLY 

Position the housing assembly against the joist. With a pencil, trace 
an outline of the housing assembly onto the ceiling. Set the housing 
aside, and cut out an opening for the fan. 

IMPORTANT

When the product is installed on the wall, the adaptor 

UP

should be facing upward. 

Prohibition 

Prohibition

Prohibition

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

www.aeropurefans.com 

1

. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty. 

2

. Before servicing or cleaning unit, switch power off at service panel and lock the 

service disconnecting means to prevent power from being switching on accidentally. If the service disconnecting means cannot 
be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 

3

. Installation work and electrical 

wiring must be done by a licensed person(s) in accordance with all applicable codes and standards, including fire-rated 
construction codes and standards. 

4

. Sufficient air is needed for proper combustion and exhausting of gases through the flue 

(chimney) of fuel burning equipment to prevent backdraft. Follow the heating equipment manufacturer’s guideline and safety 
standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 

5

. When cutting or drilling into wall or 

ceiling, do not damage electrical wiring and other hidden utilities. 

6. 

Ducted fans must always be vented to the outdoors.   

7

. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit. 

8

. This unit must be grounded. 

9

. Never place a switch where it can be reached from a tub or shower. 

10

. Not for use in kitchens. 

11

. Install fan at least 2.5 m (8.2 feet) above the floor. 

12

. WARNING: To reduce the risk of fire or electric shock, do not use this 

fan with any solid-state speed control device. 

13

. The fan must not be installed in a ceiling thermally insulated to a value greater 

than R40. 