aero pure AP70-S Quick Start Manual Download Page 1

 

BATHROOM FAN   

MODEL: AP70-S   

WARNING   

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:   

CAUTION   

1

. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

2

. This product is designed 

for installation in ceilings up to a 12/12 pitch (45 degree angle).   

DO NOT MOUNT THIS PRODUCT IN A WALL.

   

3

. To avoid motor 

bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 

4

. Please read 

specification label on product for further information and requirements. 
 

*This manual in electronic format may be downloaded from our company website or obtained from the dealer.   

CLEANING & MAINTENANCE   

For quiet and efficient operation, long life, and attractive appearance, lower or remove grille and vacuum interior of unit with the 
dusting brush attachment.   

The motor is permanently lubricated and never needs oiling.   

OPERATION   

Use an on/off switch to operate this fan. See “Connect Wiring” for details.   

ASSEMBLY INSTRUCTIONS   

MOUNT DIRECTLY TO JOIST OR I-JOIST   

Place  the  housing  assembly  in  the  opening  so  the  bottom  edge  is  flush 
with the finished ceiling. Nail the housing assembly to the joist using nails.   

POSITION THE HOUSING ASSEMBLY   

Position  the  housing  assembly  against  the  joist.  With  a  pencil,  trace  an 
outline  of  the  housing  assembly  onto  the  ceiling.  Set  the  housing  aside, 
and cut out an opening for the fan. 

DO NOT MOUNT THIS PROUCT IN A 

WALL. 

   

Prohibition   

Prohibition 

Prohibition 

READ AND SAVE THESE INSTRUCTIONS   

Installer: Leave this manual with the homeowner.   

www.aeropurefans.com   

1

.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address 

or  telephone  number  listed  in  the  warranty. 

2

.Before  servicing  or  cleaning  unit,  switch  power  off  at  service  panel  and  lock  the 

service disconnecting means to prevent power from being switching on accidentally. If the service disconnecting means cannot 
be  locked,  securely  fasten  a  prominent  warning  device,  such  as  a  tag,  to  the  service  panel. 

3

.  Installation  work  and  electrical 

wiring  must  be  done  by  a  licensed  person(s)  in  accordance  with  all  applicable  codes  and  standards,  including  fire-rated 
construction  codes  and  standards. 

4

.  Sufficient  air  is  needed  for  proper  combustion  and  exhausting  of  gases  through  the  flue 

(chimney)  of  fuel  burning  equipment  to  prev

ent  backdraft.  Follow  the  heating  equipment  manufacturer’s  guideline  and  safety 

standards such  as  those  published  by  the  National  Fire  Protection  Association  (NFPA),  and  the  American  Society  for Heating, 
Refrigeration  and  Air  Conditioning  Engineers  (ASHRAE),  and  the  local  code  authorities. 

5

. When  cutting  or drilling  into  wall  or 

ceiling, do not damage electrical wiring and other hidden utilities. 

6. 

Ducted fans must always be vented to the outdoors.   

7

. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit. 

8

. This unit must be grounded. 

9

. Never place a switch where it can be reached from a tub or shower. 

10

. Not for use in kitchens. 

11

. Install fan at least 2.5 m (8.2 feet) above the floor. 

12

. WARNING: To reduce the risk of fire or electric shock, do not use this 

fan with any solid-state speed control device. 

13

. The fan must not be installed in a ceiling thermally insulated to a value greater 

than R40. 

 

 